Determining Measurement Error for Bohler's Angle and the Effect of X-Ray Obliquity on Accuracy.

نویسندگان

  • Tyler A Gonzalez
  • Lauren K Ehrlichman
  • Alec A Macaulay
  • I Leah Gitajn
  • R James Toussaint
  • David Zurakowski
  • John Y Kwon
چکیده

BACKGROUND Bohler's angle (BA) is the most commonly utilized radiographic measurement in the study of calcaneus fractures and has been shown to be prognostic in nature. Therefore, it is critical that the measurement of BA be accurate as both therapeutic and prognostic information relies on it. Oblique lateral radiographs can be a cause of error in BA measurements. However, measurement error and the effects of X-ray beam obliquity on BA have not been established in the literature. The purpose of this study was to determine measurement error and understand the effects of X-ray beam's obliquity on the measurement of BA. METHODS A cadaver specimen was imaged using a C-arm to obtain a perfect lateral radiograph of the ankle and slightly oblique lateral views in the anterior, posterior, cephalad, and caudad directions in 5° increments (21 images). Metallic beads were then placed on the anterior calcaneal process, posterior facet, and the superior aspect of the posterior tuberosity, and the same 21 images were then obtained. The metallic beads placed on the reference radiographs allowed the authors to accurately measure BA for each image and served as reference for the corresponding test radiographs. Thirty-four orthopaedic staff members participated in the study and used DICOM measurement tool to measure BA on each of the 21 test radiographs. The measurements were then compared to the measurements of BA from the reference radiographs to determine error in measurement. RESULTS A total of 714 different measurements were obtained. Average measurement error was 6° (95% confidence interval = -4° to 15°). The difference between the observed BA measurements compared to the true BA measurements increased with increasing X-ray obliquity. CONCLUSIONS Measurement error for BA is ±6° and increases most with cephalad oblique radiographs. Orthopaedic surgeons' ability to accurately measure BA significantly decreases with increasing obliquity of the lateral radiograph. LEVELS OF EVIDENCE Level V: Cadaver bench study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Footprint as an alternative to X-ray in hallux valgus angle measurement

Background: X- ray images provide accurate and reliable data in different foot pathologies. However, the accompanied complications will limit its use for epidemiological studies and research purposes, especially in children.  Therefore, simple, accessible, and cost- effective methods such as footprint, with a good correlation with x-ray images, are needed to help diagnose different foot pa...

متن کامل

The paediatric Bohler's angle and crucial angle of Gissane: a case series

BACKGROUND Bohler's angle and the crucial angle of Gissane can be used to assess calcaneal fractures. While the normal adult values of these angles are widely known, the normal paediatric values have not yet been established. Our aim is to investigate Bohler's angle and the crucial angle of Gissane in a paediatric population and establish normal paediatric reference values. METHOD We measured...

متن کامل

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

New Method of Quality Control Test for Light and Radiation Field Coincidence in Medical Linear Accelerators

Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...

متن کامل

Acetabular morphometry for determining hip dysplasia in the Singaporean population.

PURPOSE To assess and evaluate the usefulness of 7 morphological measurements of the acetabulum in establishing the prevalence of acetabular dysplasia in the Singaporean population. METHODS Standardised plain anteroposterior radiographs of 522 hip joints of 261 asymptomatic patients (mean age, 60 years; range, 16-99 years) were evaluated. The 7 morphological measurements were centre-edge angl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot & ankle specialist

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2016