Results of proximal humeral locked plating with supplemental suture fixation of rotator cuff.

نویسندگان

  • Brian Badman
  • Mark Frankle
  • Christopher Keating
  • Leanne Henderson
  • Jordan Brooks
  • Mark Mighell
چکیده

HYPOTHESIS This study retrospectively reports the results of 81 patients with proximal humeral fractures that were treated operatively. We hypothesized that treatment of these injuries through a standardized technique of precountored locked plating and supplemental tension band suture fixation would result in improved clinical outcomes. MATERIALS AND METHODS All patients were evaluated with a minimum follow-up of 1 year. Clinical assessment was performed postoperatively with American Shoulder and Elbow Surgeons (ASES) scores and active range of motion measurements. Radiographic parameters assessed included Neer fracture pattern, fracture union, hardware failure, the presence of avascular necrosis, and medial calcar length and stability. Fractures were classified as 4-part in 14 (17%), 3-part in 41 (51%), and 2-part in 26 (32%). RESULTS The average ASES score was 80 (range, 27-100). The final range of motion averaged 131° of anterior elevation and 41° of external rotation. Fracture union was achieved in all patients, and there were no tuberosity failures. Complications included intraarticular screw penetration in 3 (3.7%) and avascular necrosis in 5 (6.2%). DISCUSSION Locked plating and supplemental tension band fixation can lead to fracture union and favorable outcomes. Restoration of the medial calcar and supplemental suture fixation may decrease the incidence of hardware-related complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tension suture fixation using 2 washers for proximal humeral fractures.

The surgical treatment for proximal humeral fractures is challenging, especially in patients with osteoporosis. Locking plates and intramedullary nails have been widely used with satisfactory results, but previously reported complications have not been substantially reduced. Several authors have emphasized the importance of maintaining soft tissues around the proximal humerus with respect to li...

متن کامل

Quality of life after antegrade intramedullary nail fixation of humeral fractures: a survey in a selected cohort of Brazilian patients

Background The treatment of humeral fractures remains controversial. Systematic reviews demonstrate similar results between dynamic compression plating and locked intramedullary nailing in the surgical treatment of these fractures. However, it appears that antegrade intramedullary nailing causes higher residual pain in the shoulder. The proposal of this work is to evaluate through the WORC prot...

متن کامل

Biomechanical performance of rotator cuff repairs with humeral rotation: a new rotator cuff repair failure model.

BACKGROUND Traditional biomechanical evaluations of rotator cuff repair techniques employ cyclic loading of the supraspinatus tendon in an isolated medial direction. PURPOSE This study was conducted to evaluate 2 different rotator cuff repair techniques that are currently the subject of debate with cyclic loading and with internal and external humeral rotation to better simulate postoperative...

متن کامل

Proximal Humeral Nonunions: Surgical Technique with Fibular Strut Allograft and Fixed-Angle Locked Plating

Nonunions of the proximal humerus, although uncommon, are challenging for even the experienced upper extremity specialist. The bone quality is typically poor, and the proximal bone stock is limited. These patients often possess multiple comorbidities contributing to the development of the nonunion. Although many treatment options exist, results have been mixed with no definitive surgical techni...

متن کامل

Is Loss of Fixation Following Locked Plating of Proximal Humeral Fractures Related to the Number of Screws and Their Positions in the Humeral Head?

The aim of the study was to examine the correlation between the chosen position of screws and the complications observed in patients who underwent locked plating of proximal humeral fractures. We evaluated radiographs of 367 patients treated by locked-plating for proximal humeral fractures. Radiographs were taken at one day, 6 weeks, 3 months and 6 months after surgery, and were analyzed for se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2011