Time-Resolved Detection of X-rays Using Large-Area Avalanche Photodiodes

نویسندگان

  • A. Q. R. Baron
  • S. L. Ruby
چکیده

We have measured the efficiencies and time responses of several largearea (200 and 80 mm2) beveled-edge avalanche photodiodes to x-rays of energy 6–20 keV in a photon counting mode. The diodes were used with avalanche gains of 102 to 103. Detector efficiency varied from ∼50% at 8 keV to ∼5% at 20 keV, while the time resolution was ∼1/2 ns with a tail out to longer times (∼5 ns). The duration of the tail may be reduced (<2 ns) by selecting only larger pulses from the diode (increasing the discriminator threshold). These results are well explained by a simple physical picture of the device: the fast response is due to x-rays absorbed in the depletion layer, and the tail results from x-rays absorbed in a low-field undepleted region in front of the diode. For one device, the total active thickness (depletion and low field region) was measured to be 49 μm and the low field region to be 9 μm. Submitted to Nuclear Instruments and Methods in Physics Research * Work Supported by Department of Energy contract DE-AC03-76SF00515. Time Resolved Detection of X-rays Using Large Area Avalanche Photodiodes * A.Q.R. Baron and S.L. Ruby Stanford Linear Accelerator Center Stanford Synchrotron Radiation Laboratory Stanford, CA 94309, USA

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of large area avalanche photodiodes to low energy x rays.

For an experiment to study neutron radiative beta-decay, we operated large area avalanche photodiodes (APDs) near liquid nitrogen temperature to detect x rays with energies between 0.2 keV and 20 keV. Whereas there are numerous reports of x ray spectrometry using APDs at energies above 1 keV, operation near liquid nitrogen temperature allowed us to reach a nominal threshold of 0.1 keV. However,...

متن کامل

Recent progress of avalanche photodiodes in high-resolution X-rays and γ-rays detection

We have studied the performance of large area avalanche photodiodes (APDs) recently developed by Hamamatsu Photonics K.K, in high-resolution X-rays and γrays detections. We show that reach-through APD can be an excellent soft X-ray detector operating at room temperature or moderately cooled environment. We obtain the best energy resolution ever achieved with APDs, 6.4 % for 5.9 keV X-rays, and ...

متن کامل

Application of large-area avalanche photodiodes to energy-dispersive x-ray fluorescence analysis

The performance of several large-area avalanche photodiodes (LAAPDs) for application to x-ray spectrometry at room temperature was investigated. Optimum detector performance was obtained for gains of about 50–70. Good energy linearity of the LAAPDs’ response to x-rays was observed up to energies of about 25 keV. For this energy range the space charge effects are negligible for gains below 100–1...

متن کامل

Application of large-area avalanche photodiodes to X-ray spectrometry of muonic atoms

Large-area avalanche photodiodes have been investigated as 1.9-keV X-ray detectors for the muonic hydrogen Lamb-shift experiment. We report experimental tests carried out for evaluation of the avalanche photodiode capabilities for X-ray detection in the intense radiation and low counting rate environment of experiments with muonic atoms. Several muonic atoms were used and it was shown that the ...

متن کامل

Improved x-ray detection and particle identification with avalanche photodiodes.

Avalanche photodiodes are commonly used as detectors for low energy x-rays. In this work, we report on a fitting technique used to account for different detector responses resulting from photoabsorption in the various avalanche photodiode layers. The use of this technique results in an improvement of the energy resolution at 8.2 keV by up to a factor of 2 and corrects the timing information by ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997