Simultaneous determination of tartaric acid and potassium in wines using a multicommuted flow system with dialysis.

نویسندگان

  • Sara M Oliveira
  • Teresa I M S Lopes
  • Ildikó V Tóth
  • António O S S Rangel
چکیده

A multicommuted flow system with the propulsion device placed before detection is proposed for the determination of tartaric acid and free potassium in table and Port wines. A dialysis unit was introduced to increase sample dilution and minimize matrix interferences. The determination of tartaric acid was based on the spectrophotometric monitorization of the complex formed by the dialyzed analyte with vanadate. Potentiometric measurement of potassium was carried out through an ion selective tubular electrode. Dynamic linear ranges of 0.500-5.00gL(-1) and 390-2000mgL(-1) were achieved for tartaric acid and potassium determinations, respectively. Detection and quantification limits of 0.1 and 0.4gL(-1) of tartaric acid were obtained, respectively. For the potentiometric determination, a detection limit of 1x10(-4)molL(-1) was achieved. The accuracy of the method was assessed by analysis of 30 wine samples by the proposed methodology and manual procedures. There were no statistical differences between the 2 sets of results, in both determinations. Relative standard deviations lower than 2.1 and 2.4% were attained by the spectrophotometric and potentiometric measurements, respectively. A determination rate of 52h(-1) was achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sequential determination of titratable acidity and tartaric acid in wines by flow injection spectrophotometry

A flow injection manifold is proposed for the sequential determination of titratable (total) acidity based on a pseudotitration and of tartaric acid based on the formation of a coloured vanadate complex. The method involves in-line dialysis prior to injection to avoid interference from the sample background absorption in the spectrophotometric detection. The changes in the colour of both reacti...

متن کامل

Determination of polyphenols in wines by reaction with 4-aminoantipyrine and photometric flow-injection analysis.

A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to sele...

متن کامل

An Automated Multicommuted Flow Analysis Procedure for Photometric Determination of Reducing Sugars in Wine Employing a Directly Heated Flow‐Batch Device

This work presents an automated analytical procedure for the photometric determination of reducing sugars in wines. The procedure is based on the reaction of reducing sugars with potassium hexacyanoferrate(III) in an alkaline medium, and was implemented employing a multicommuted flow analysis (MCFA) approach. Sample heating to promote the reaction was accomplished using a flow-batch device, whi...

متن کامل

Determination of tartaric acid in wines by FIA with tubular tartrate-selective electrodes.

A flow injection analysis (FIA) system comprising a tartrate-(TAT) selective electrode has been developed for determination of tartaric acid in wines. Several electrodes constructed for this purpose had a PVC membrane with a complex of quaternary ammonium and TAT as anion exchanger, a phenol derivative as additive, and a more or less polar mediator solvent. Characterization of the electrodes sh...

متن کامل

Instrumentation and Automated Photometric Titration Procedure for Total Acidity Determination in Red Wine Employing a Multicommuted Flow System

An automated procedure for photometric titration of red wine and associated instrumentation is described. The procedure was based on the flow-batch approach implemented employing multicommutation. The photometric detection was carried out using a homemade LED-based photometer. The mixing device, LED, and photodetector were attached to the titration chamber in order to form a compact and small-s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 81 4-5  شماره 

صفحات  -

تاریخ انتشار 2010