Evaluation of cardiac parameters using electrical impedance plethysmography.

نویسندگان

  • C Corciovă
  • M Turnea
  • Daniela Matei
  • D Andritoi
چکیده

UNLABELLED Impedance plethysmography is a method for determining changes in body tissue volumes, based on the measurement of electric impedance at the body surface. Because it is a non-invasive and cost-effective method to measure and analyze hemodynamics, it would bring to physiologists very important diagnostic information for the continuous care of critical patients with hemodynamic disorders. METHODS This study aimed at acquiring non-invasively and at analyzing plethysmografic waves by measuring the electrical impedance. For measurements we built a device that was designed as an injection module with a microcontroller, a programmable waveform generator, and a voltage controlled current source which generates a sinusoidal pulse with adjustable frequency (10-200 kHz) and adjustable intensity. In output, the device delivers an analogical signal representing the variation of the impedance of the explored section. The acquisition of the bioimpedance signal on PC was made easier by the use of a national instrument data acquisition device, the NI USB 6009. RESULTS The bioimpedance signal processing, the user interface and the display were managed by MATLAB. Sample impedance data for a test subject are presented. From the experimental results, it is shown that the proposed bioimpedance measuring system could provide good performance over the frequency range for central or peripheral territory. CONCLUSION The clinical importance of these findings is that this method can measure vascular parameters noninvasively, continuously and more conveniently in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac hemodynamic profile and its correlates by Impedance plethysmography in normal individuals of Central India.

Evaluation of hemodynamic profile by impedance plethysmography (IPG) provides functional expression of cardiovascular performance with efficacy of treatment. Objective of this study was to establish normative hemodynamic parameters by IPG. In this cross-sectional study hemodynamic parameters including cardiac output (CO), Stroke volume (SV), left ventricular ejection time (LVET), impedance (Zo)...

متن کامل

Development of forearm impedance plethysmography for the minimally invasive monitoring of cardiac pumping function

It is essential to continuously and non-invasively monitor the cardiac pumping function in clinical setting. Thus, the study aimed to explore a regional impedance phethysmographic method to assess the changes in stroke volume. To do this, we developed a plethysmographic device that was capable of delivering a single-frequency current with constant amplitude and of recording electrical impedance...

متن کامل

Implantable Impedance Plethysmography

We demonstrate by theory, as well as by ex vivo and in vivo measurements that impedance plethysmography, applied extravascularly directly on large arteries, is a viable method for monitoring various cardiovascular parameters, such as blood pressure, with high accuracy. The sensor is designed as an implant to monitor cardiac events and arteriosclerotic progression over the long term.

متن کامل

Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review.

Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal...

متن کامل

Control of pacemaker rate by impedance-based respiratory minute ventilation.

Several studies have shown that the capability for exercise can be increased in patients with pacemakers by means of adjusting the rate. Respiration is one of the parameters considered for rate control. The aim of our study was to determine how respiratory parameters such as ventilation, tidal volume, and respiratory rate are capable of controlling the pacemaker rate, especially when measured i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista medico-chirurgicala a Societatii de Medici si Naturalisti din Iasi

دوره 116 3  شماره 

صفحات  -

تاریخ انتشار 2012