Effects of aeration cycles on nitrifying bacterial populations and nitrogen removal in intermittently aerated reactors.

نویسندگان

  • Cesar Mota
  • Melanie A Head
  • Jennifer A Ridenoure
  • Jay J Cheng
  • Francis L de Los Reyes
چکیده

The effects of the lengths of aeration and nonaeration periods on nitrogen removal and the nitrifying bacterial community structure were assessed in intermittently aerated (IA) reactors treating digested swine wastewater. Five IA reactors were operated in parallel with different aeration-to-nonaeration time ratios (ANA). Populations of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) were monitored using 16S rRNA slot blot hybridizations. AOB species diversity was assessed using amoA gene denaturant gradient gel electrophoresis. Nitrosomonas and Nitrosococcus mobilis were the dominant AOB and Nitrospira spp. were the dominant NOB in all reactors, although Nitrosospira and Nitrobacter were also detected at lower levels. Reactors operated with the shortest aeration time (30 min) showed the highest Nitrosospira rRNA levels, and reactors operated with the longest anoxic periods (3 and 4 h) showed the lowest levels of Nitrobacter, compared to the other reactors. Nitrosomonas sp. strain Nm107 was detected in all reactors, regardless of the reactor's performance. Close relatives of Nitrosomonas europaea, Nitrosomonas sp. strain ENI-11, and Nitrosospira multiformis were occasionally detected in all reactors. Biomass fractions of AOB and effluent ammonia concentrations were not significantly different among the reactors. NOB were more sensitive than AOB to long nonaeration periods, as nitrite accumulation and lower total NOB rRNA levels were observed for an ANA of 1 h:4 h. The reactor with the longest nonaeration time of 4 h performed partial nitrification, followed by denitrification via nitrite, whereas the other reactors removed nitrogen through traditional nitrification and denitrification via nitrate. Superior ammonia removal efficiencies were not associated with levels of specific AOB species or with higher AOB species diversity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High levels of nitrifying bacteria in intermittently aerated reactors treating high ammonia wastewater.

Changes in the fractions of ammonia-oxidizing bacteria and nitrite-oxidizing bacteria in two laboratory-scale reactors were investigated using 16S rRNA probe hybridizations. The reactors were operated in intermittent aeration mode and different aeration cycles to treat anaerobically digested swine wastewater with ammonia concentrations up to 175 mg NH(3)-N/L. High ammonia removals (>98.8%) were...

متن کامل

Sequentially aerated membrane biofilm reactors for autotrophic nitrogen removal: microbial community composition and dynamics

Membrane-aerated biofilm reactors performing autotrophic nitrogen removal can be successfully applied to treat concentrated nitrogen streams. However, their process performance is seriously hampered by the growth of nitrite oxidizing bacteria (NOB). In this work we document how sequential aeration can bring the rapid and long-term suppression of NOB and the onset of the activity of anaerobic am...

متن کامل

Assessment of nitrogen and phosphorus removal in an intermittently aerated sequencing batch reactor (IASBR) and a sequencing batch reactor (SBR).

Biological nitrogen and phosphorus removal was investigated in an intermittently aerated sequencing batch reactor (IASBR) and a sequencing batch reactor (SBR). The removal efficiencies of ammonium-nitrogen (NH4(+)-N) were 100% in both reactors in steady operation state. The total nitrogen (TN) removal efficiencies were 90.4% in the IASBR and 79.3% in the SBR, while the total phosphorus (TP) rem...

متن کامل

Microbial structure and nitrogen compound conversions in aerobic granular sludge reactors with non-aeration phases and acetate pulse feeding

A technological system was developed for efficient nitrogen removal from real digester supernatant in a single reactor with shortened aeration to increase the economical aspects of wastewater treatment. The supernatant (600 mg TKN/L, low COD/N ratio of 2.2) was treated in batch reactors with aerobic granules (GSBRs) to test how one, two, or three non-aeration phases and acetate pulse feeding in...

متن کامل

A bench-scale aeration study using batch reactors on swine manure stabilization to control odour in post treatment storage.

A bench-scale study on swine manure stabilization for odour control was conducted using batch aeration reactors. In trial 1, two aeration lengths, i.e., 0.5 and 4.0 day, were used under uncontrolled ambient temperature that increased gradually over the experimental period. While in trial 2, a 16.0-day aeration scheme was employed under constant 17 degrees C. An airflow rate of 1.2L/s/m(3) was u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 71 12  شماره 

صفحات  -

تاریخ انتشار 2005