Esophageal multichannel intraluminal impedance and pH testing in the study of apparent life threatening episode incidents in infants.
نویسندگان
چکیده
INTRODUCTION The conventional 24-hour pH monitoring is the gold standard for the diagnosis of gastro-esophageal reflux (GER), a possible cause of Apparent Life Threatening Episodes (ALTE). However, multichannel intraluminal impedance (MII) may provide advantages. OBJECTIVES Comparison of the results of MII and pH monitoring in patients undergoing MII-pH monitoring in the 3-year study period because of having suffered from ALTE. MATERIAL AND METHODS Prospective study of MII-pH monitoring performed in our unit to infants < 12 months of ageadmitted for ALTE for a 3-year period. RESULTS Thirty nine patients studied. 2,692 pH monitoring episodes, with median of 24 (IQ: 15-44) episodes/patient, 1.30 (IQ: 0.80-2.60) reflux/hour, 1 (IQ: 0-4) reflux episode > 5 min per patient and clearance of 1.20 (IQ: 0.70-2.20) min/reflux. With pH monitoring analysis, 14 children (35.9 %) could have been diagnosed as GER (8 mild, 4 moderate and 2 severe) based on the classical criteria. MII identified a total of 8,895 events; only 3,219 among them were refluxes, with a median of 75 (IQ: 54-111) per patient, 1.30 (IQ: 1.3-2.6) episodes/hour). With MII-pH monitoring combination there were 21.60 (SD 15.21) acid reflux episodes, 67.33 weekly acid (SD 32.09) and 3.34 (SD 7.23) non-acid, being finally diagnosed 33 patients as GER. CONCLUSIONS The association of pH monitoring and MII provides additional information that improves GER diagnostic performance without posing any additional risk to the infant patient. The non-acid/weekly acid refluxes, not detected by pH monitoring, account for a high percentage of episodes, this may have diagnostic and therapeutic significance, especially in infants. Further studies are needed to assess the normality of MMI in pediatric patients.
منابع مشابه
Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children
Background Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determ...
متن کاملDiagnostic difficulties during combined multichannel intraluminal impedance and pH monitoring in patients with esophagitis or Barrett's esophagus.
Gastroesophageal reflux disease (GERD) is one of the most common esophageal diseases in developed countries. It is widely believed that GERD symptoms are caused by acid refluxate within the esophagus, so ambulatory 24 hour pH-monitoring became the gold standard in detecting gastroesophageal reflux. Traditional ambulatory pH monitoring is unable to detect a gastroesophageal reflux with pH >4. Th...
متن کاملPrinciples of Combined Esophageal Impedance-ph Monitoring in Children: Indications, Benefits and Limitations
The standard test for suspected gastroesophageal refl ux is pH monitoring. However, the majority of gastroesophageal refl ux episodes in infants and children are nonacidic (pH > 4) and extraesophageal symptoms apparently can be caused by both acidic (pH < 4) and nonacidic refl ux. In order to overcome these aspects, a new technique has been developed and placed under scrutiny in the past twenty...
متن کاملEsophageal Multichannel Intraluminal Impedance and pH Monitoring in the Evaluation of Achalasia and Gastroesophageal Reflux Disease in a Child with Down Syndrome: a Case Report.
We report the case of a rare association between achalasia and Down syndrome in a child presenting with symptoms that suggest a gastroesophageal reflux. Evaluation of the patient with 24-hour multichannel intraluminal impedance and pH recording and upper endoscopy lead to the diagnosis of achalasia. However, the persistence of the symptoms after the concurrent surgical myomectomy and fundoplica...
متن کاملClinical Applications of Esophageal Multichannel Intraluminal Impedance Testing.
Multichannel intraluminal impedance is a relatively new technology that allows detection of bolus movement in the gastrointestinal tract without the use of radiation. In clinical applications it is combined with manometry, allowing a better evaluation of the functional characteristics (ie, bolus transit) of esophageal motility abnormalities. When combined with pH monitoring, it provides more co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de enfermedades digestivas : organo oficial de la Sociedad Espanola de Patologia Digestiva
دوره 106 3 شماره
صفحات -
تاریخ انتشار 2014