Evaluation of bond strength of silorane and methacrylate based restorative systems to dentin using different cavity models

نویسندگان

  • Stephano Zerlottini ISAAC
  • Ana Claudia Pietrobom BERGAMIN
  • Cecília Pedroso TURSSI
  • Flávia Lucisano Botelho do AMARAL
  • Roberta Tarkany BASTING
  • Fabiana Mantovani Gomes FRANÇA
چکیده

OBJECTIVE The aim of this in vitro study was to evaluate the microtensile bond strength (µTBS) to dentin of two different restorative systems: silorane-based (P90), and methacrylate-based (P60), using two cavity models. MATERIAL AND METHODS Occlusal enamel of 40 human third molars was removed to expose flat dentin surface. Class I cavities with 4 mm mesial-distal width, 3 mm buccal-lingual width and 3 mm depth (C-factor=4.5) were prepared in 20 teeth, which were divided into two groups (n=10) restored with P60 and P90, bulk-filled after dentin treatment according to manufacturer's instructions. Flat buccal dentin surfaces were prepared in the 20 remaining teeth (C-factor=0.2) and restored with resin blocks measuring 4x3x3 mm using the two restorative systems (n=10). The teeth were sectioned into samples with area between 0.85 and 1.25 mm2 that were submitted to µTBS testing, using a universal testing machine (EMIC) at speed of 0.5 mm/min. Fractured specimens were analyzed under stereomicroscope and categorized according to fracture pattern. Data were analyzed using ANOVA and Tukey Kramer tests. RESULTS For flat surfaces, P60 obtained higher bond strength values compared with P90. However, for Class I cavities, P60 showed significant reduction in bond strength (p<0.05). No statistical difference between restorative systems was shown for Class I cavity model (p>0.05), or between Class I Cavity and Flat Surface group, considering P90 restorative system (p>0.05). Regarding fracture pattern, there was no statistical difference among groups (p=0.0713) and 56.3% of the fractures were adhesive. CONCLUSION It was concluded that methacrylate-based composite µTBS was influenced by cavity models, and the use of silorane-based composite led to similar bond strength values compared to the methacrylate-based composite in cavities with high C-factor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Shear Bond Strength of Silorane and Methacrylate-Based Composites to IPS Empress 2 Ceramic with Various Surface Treatments

Objectives: Treatment of chipped or fractured porcelain with composite resin is considered as an economic treatment for minor fractures in ceramics. The aim of this study was to evaluate the effect of different ceramic surface treatments on bond strength of methacrylate-based and silorane-based composite resin to IPS Empress 2. Methods: Sixty IPS Empress 2 ceramic discs were fabrica...

متن کامل

Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

OBJECTIVES The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. MATERIALS AND METHODS Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesiv...

متن کامل

Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials

OBJECTIVES This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. MATERIAL AND METHODS The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat ...

متن کامل

Comparison of Microtensile Bond Strength of Silorane-Based Composite with the Conventional Methacrylate Composite to the Dentin of Primary Teeth

STATEMENT OF PROBLEM The bond strength between restorative material and tooth structure is so important for conduction of durable restoration. Considering the recent attention to low shrinkage composite resins, evaluation of micro tensile bond strength of these materials would be valuable. OBJECTIVES To compare the microtensile bond strength of silorane composite resin (Filtek P90) with the c...

متن کامل

Light-curing time and aging effects on the nanomechanical properties of methacrylate- and silorane-based restorations.

SUMMARY The aim of this study was to assess the influence of light-curing time on the nanohardness (H) and reduced elastic modulus (Er) of components (underlying dentin, hybrid layer, adhesive, and composite) of methacrylate- and silorane-based restorations after 24 hours and six months of storage. Class II slot preparations were carried out in human molars (n=3) and restored with methacrylate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2013