Patient Alerting Features in Implantable Defibrillators
نویسندگان
چکیده
Implantable cardioverter defibrillators (ICD) are state of the art devices for the primary and secondary prevention of sudden cardiac death.1 As a result, the use of ICDs has increased remarkably over the past years. Since they are life saving devices and because dysfunction can cause fatal pro-arrhythmia2, monitoring of their proper functioning is vital for patient welfare. To date, conventional ICD follow-up is in the form of device clinics where the ICD is interrogated and programmed periodically and the appropriate system function is ensured. Remote device monitoring has recently been introduced and may provide advantages especially for patients living further away from the implanting center.3 Another important feature of current ICDs is the ability to monitor the device function and the patient clinical status, and to alert the patient if evidence for system dysfunction or adverse clinical events is found. This article gives an overview about patient alerting features of current ICDs.
منابع مشابه
Programming implantable cardioverter/defibrillators and outcomes
Implantable cardioverter-defibrillators are complex technical devices with a multitude of programming options for the physician. In recent years, numerous randomized trials have been performed to define the optimal programming strategies and have provided valuable insights, especially in primary prevention patients. This article provides an actual overview on the existing evidence on the most i...
متن کاملThe Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the Perioperative Management of Patients with Implantable Defibrillators, Pacemakers and Arrhythmia Monitors: Facilities and Patient Management
a t C r a t a R The Heart Rhythm Society (HRS)/American Society of Anesthesiologists (ASA) Expert Consensus Statement on the Perioperative Management of Patients with Implantable Defibrillators, Pacemakers and Arrhythmia Monitors: Facilities and Patient Management This document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the A...
متن کاملElectronic article surveillance systems and interactions with implantable cardiac devices: risk of adverse interactions in public and commercial spaces.
Electronic article surveillance (EAS) systems are widely implemented in public spaces and can adversely affect the performance of pacemakers and implantable cardioverter defibrillators. The interaction between implantable devices and EAS systems is a serious problem that can be minimized through appropriate facility design. Careful facility design and employee education along with patient vigil...
متن کاملTroubleshooting implantable cardioverter-defibrillator related problems.
These include: Data supplement http://heart.bmj.com/cgi/content/full/94/5/649/DC1 "web only references" References http://heart.bmj.com/cgi/content/full/94/5/649#BIBL This article cites 21 articles, 11 of which can be accessed free at: Rapid responses http://heart.bmj.com/cgi/eletter-submit/94/5/649 You can respond to this article at: service Email alerting the top right corner of the article R...
متن کاملElectromagnetic Interference With Implantable Cardiac Devices
Although pacemakers and implantable cardioverter-defibrillators (ICDs) are subject to electromagnetic interference (EMI) from many sources, relatively few are capable of causing clinically significant interference. However, in the rapidly evolving technology -driven environment in which we live, new devices that could theoretically cause interference with implanted devices constantly appear bot...
متن کامل