A comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.
نویسندگان
چکیده
OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bilateral examination time for Goldmann fields was 10 +/- 2 minutes and for Humphrey fields was 50 +/- 10 minutes (P<.001, n = 12). Superior fields at the 12:00 meridian were 46 degrees +/- 6 degrees taped, and 28 degrees +/- 12 degrees untaped for Goldmann perimetry (P<.001), and 38 degrees +/- 8 degrees taped, and 24 degrees +/- 12 degrees untaped for Humphrey perimetry P<.001). Goldmann field loss was 18 degrees +/- 9 degrees (taped minus untaped). Humphrey field loss was 14 degrees +/- 13 degrees (P<.04, n = 24). Mean Goldmann radial fields were 56 degrees +/- 6 degrees taped and 39 degrees +/- 13 degrees untaped (P<.001). Goldmann superior hemifield areas were 5,167 +/- 964 degrees2 taped and 2,830 +/- 1,466 degrees2 untaped (P<.001). Humphrey mean vertical superior hemifield was 37 degrees +/- 9 degrees taped and 21 degrees +/- 11 degrees untaped (P<.001). Mean sensitivity of Humphrey fields was 15 +/- 3 dB taped and 9 +/- 5 dB untaped (P<.001). Mean vertical center of gravity was 23 degrees +/- 3 degrees taped and 16 degrees +/- 5 degrees untaped (P <.001). CONCLUSION Goldmann manual kinetic and Humphrey automated static visual field testing are both effective in documenting ptosis associated visual field loss. Humphrey automated ptosis fields, as performed in this study, require longer examination times than Goldmann manual fields and may be a less sensitive indicator of field loss.
منابع مشابه
Automated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.
OBJECTIVES To create a fully automated, combined perimetry program consisting of a static examination and a kinetic examination, and to compare the results of this test with standard static and kinetic visual fields (VFs). METHODS Fifty-six patients (74 eyes) undergoing neuro-ophthalmic or glaucoma evaluation who had standard static or kinetic perimetry examinations underwent the combined per...
متن کاملComparison of Octopus Semi-Automated Kinetic Perimetry and Humphrey Peripheral Static Perimetry in Neuro-Ophthalmic Cases
Aim. To compare semikinetic perimetry (SKP) on Octopus 900 perimetry to a peripheral static programme with Humphrey automated perimetry. Methods. Prospective cross-section study comparing Humphrey full field (FF) 120 two zone programme to a screening protocol for SKP on Octopus perimetry. Results were independently graded for presence/absence of field defect plus type and location of defect. Re...
متن کاملComparison of Automated Kinetic and Static Visual Fields in Neuro-ophthalmology Patients
Eighty-three patients with various neuro-ophthalmic diseases were submitted to a standard automated protocol including kinetic and static perimetry The kinetic protocol included one peripheral, one intermediate and one central isopter and a blind spot contour determination The static protocol included fast thresholding of 80 points within the pericentral field and a 4-2-2-2 foveolar threshold d...
متن کاملA comparison of tangent screen, goldmann, and humphrey perimetry in the detection and localization of occipital lesions.
OBJECTIVE To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions. DESIGN Prospective consecutive comparative case series. PARTICIPANTS Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied. ...
متن کاملReclaiming the Periphery: Automated Kinetic Perimetry for Measuring Peripheral Visual Fields in Patients With Glaucoma.
Purpose Peripheral vision is important for mobility, balance, and guidance of attention, but standard perimetry examines only <20% of the entire visual field. We report on the relation between central and peripheral visual field damage, and on retest variability, with a simple approach for automated kinetic perimetry (AKP) of the peripheral field. Methods Thirty patients with glaucoma (median...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 118 1 شماره
صفحات -
تاریخ انتشار 2000