Title Page Coefficient of Determination Sita Swedish Interactive Threshold Algorithms Swap Short-wavelength-automated-perimetry Va Visual Acuity Wwp White-on-white Perimetry 3

نویسندگان

  • Boel Bengtsson
  • Anders Heijl
  • Elisabet Agardh
چکیده

has been peer-reviewed but does not include the final publisher proof-corrections or journal pagination. Citation for the published paper: Bengtsson, B and Heijl, A and Agardh, E "Visual fields correlate better than visual acuity to severity of diabetic retinopathy." Access to the published version may require journal subscription. Title: Visual fields correlate better than visual acuity to severity of diabetic retinopathy Short title: B Bengtsson et al.: Visual fields and visual acuity in diabetic retinopathy Abstract Purpose: To compare outcome of perimetric and visual acuity tests in patients with diabetic retinopathy. Methods: Fifty-nine diabetic patients with different degrees of retinopathy were subjected to stereo fundus photography according to the Early Treatment Diabetic Retinopathy Study (ETDRS), and fluorescein angiography. Conventional White-White-Perimetry (WWP) and Short-Wavelength-Automated-Perimetry (SWAP) were performed and analysed with reference to normal values. Visual acuity (VA) was measured with ETDRS charts. Results: Regression analysis revealed that VA was significantly associated with increasing severity of retinopathy according to the ETDRS scale when VA was estimated by counting LogMar Scores, but not by the conventional reading of the smallest line that could be seen,. VA decreased by 0.02 LogMar/ETDRS step (p=0.03). Degree of visual field loss was significantly associated with increasing severity of retinopathy according to the ETDRS scale, perimetric sensitivity decreasing by 0.44 dB/ETDRS step (p=0.0001) using WWP, and by-0.40 dB/ETDRS step (p=0.04) with SWAP. Area of the foveal avascular zone (FAZ) and adjacent perifoveal intercapillary areas (PIAs) also affected the central visual field as obtained both by WWP, –2.6 dB/ mm 2 (p=0.03), and by SWAP, –7.9dB/ mm 2 (p=0.002), but did not affect VA. The regression model fit for peripheral retinopathy according to the ETDRS scale was better using WWP than SWAP or VA, while SWAP testing was superior to both WWP and VA when measuring effects caused by enlarged FAZ and PIAs. Conclusion: Perimetry can provide more useful information than VA on functional loss in diabetic retinopathy, particularly when the perifoveal capillary network is damaged. Abbrevations: dB decibel ETDRS Early Treatment Diabetic Retinopathy Study FAZ foveal avascular zone Fig. Figure HFA Humphrey Field Analyzer LOCS Lens Opacities Classification System LogMar logarithm of minimum angle of resolution MD Mean Deviation PIA perifoveal intercapillary area r 2

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new rapid threshold algorithm for short-wavelength automated perimetry.

PURPOSE To develop and test a short and reliable visual field threshold program for the early detection of glaucomatous visual field loss, by adapting the Swedish interactive test algorithm (SITA) to short-wavelength-automated-perimetry (SWAP). METHODS Computer simulations were performed to test the accuracy of several versions of SITA SWAP, and to optimize speed versus reliability. The selec...

متن کامل

Comparing the full-threshold and Swedish interactive thresholding algorithms for short-wavelength automated perimetry.

PURPOSE To compare the Swedish interactive thresholding algorithm (SITA) with the full-threshold (FT) strategy for short-wavelength automated perimetry (SWAP). METHODS One eye of 286 patients with glaucomatous optic neuropathy (GON) and 289 age-matched participants without GON from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGE...

متن کامل

Variability in short-wavelength automated perimetry among peri- or postmenopausal women: a dependence on phyto-oestrogen consumption?

PURPOSE To determine whether the hill of vision for Short-Wavelength Automated Perimetry (SWAP) is shallower for women who consume phyto-oestrogen-rich foods than for women who do not. METHODS Visual field data were compared for two groups of healthy amenorrhoeic women 48-69 years-old with normal vision and not using hormone replacement: (1) 24 subjects who reported consuming soy and/or flax ...

متن کامل

Effect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma

PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinte...

متن کامل

Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.

PURPOSE To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma. METHODS One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006