Optimal cut-off value for cardiac troponin I in ruling out Type 5 myocardial infarction.

نویسندگان

  • Peter Hartmund Jørgensen
  • Mads Nybo
  • Marianne Kjær Jensen
  • Poul Erik Mortensen
  • Tina Svenstrup Poulsen
  • Axel Cosmus Pyndt Diederichsen
  • Hans Mickley
چکیده

OBJECTIVES The clinical classification of myocardial infarction (MI) into five types was introduced in 2007 as a component of the universal definition. A Type 5 MI was defined as a MI related to coronary artery bypass surgery. In a setting of patients undergoing elective coronary artery bypass grafting, we set out (i) to describe the pattern of multiple serial cardiac troponin I (cTnI) measurements within 72 h postoperatively and (ii) to determine the optimal cardiac troponin I cut-off value in ruling in or ruling out a Type 5 MI. METHODS In 2011-2012, patients with two- and three-vessel disease scheduled for elective on-pump coronary artery bypass grafting were considered. Samples for cTnI were drawn before and 0, 2, 4, 6, 12, 24, 48 and 72 h after surgery. Analysis for cardiac troponin I was performed by use of the Abbott Architect c16000 system with an upper reference limit (URL) of 30 ng/l. The diagnosis of a Type 5 MI was prospectively made by a consultant cardiologist and was based on clinical, electrocardiographic and imaging data together with routine sampling and measurements of cTnI, but without knowledge of the results of serial study cTnI measurements. RESULTS Of the 141 eligible patients, 99 (70%) qualified for final enrollment. In 8 patients (8%), the clinical diagnosis of a Type 5 MI was made. Patients without Type 5 MI (n = 91) had a median cTnI peak value of 7675 ng/l compared with 20 500 ng/l in Type 5 MI patients (P = 0.01). By use of receiver operating characteristic curves, optimal cut-off values for identifying Type 5 MI were defined as 7970 ng/l (corresponding to 266 times the URL) 12 h postoperatively and 9950 ng/l (corresponding to 331 times the URL) 24 h postoperatively. These cut-off values resulted in negative predictive values of 0.99 (12 h) and 0.99 (24 h). Positive predictive values were 0.23 (12 h) and 0.35 (24 h). CONCLUSIONS In clinically stable patients undergoing elective coronary artery bypass grafting, measurements of cTnI are useful in ruling out a Type 5 MI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Diagnostic Value of Cardiac Troponin T in the Detection of Acute Myocardial Infarction in Hospital USM Patients

Acute myocardial infarction (AMI) was defined based on clinical findings, ECG abnormalities and cardiac enzymes. However with sensitive marker such as troponin the definition has been refined. In this study two cut-off values of troponin T (0.03ng/mL and 0.1ng/mL) were compared with the final diagnosis of AMI made by the physician. This was a retrospective study to determine the efficiency of c...

متن کامل

تشخیص بعد از مرگ انفارکت میوکارد در مراحل اولیه با استفاده از مارکر تروپونین به روش ایمنوهیستوشیمی

Background: The postmortem diagnosis of early myocardial infarction is a perplexing affair in forensic pathology. The routine evaluations of autopsied hearts including macroscopic examination and study of H;E stained sections are often not contributory. Some other methods like electron microscopy need sophisticated equipments which are not available in all pathology laboratories. Methods: In a...

متن کامل

The most sensitive double-marker method of cardiac isoenzymes of creatinine kinase, troponin I, and myoglobin in different time periods for diagnosing acute myocardial infarction

  Purpose: Myocardial infarction is among the most common diagnoses in patients admitted   to hospitals in western countries, and its rapid diagnosis is of utmost importance. This study   was conducted to determine the most sensitive double-marker cardiac isoenzyme of creatinine   kinase, troponin I, and myoglobin for diagnosing acute myocardial infarction.   Materials and Methods: This was an ...

متن کامل

Clinical application of high-sensitivity cardiac troponin T test in acute myocardial infarction diagnosis.

The aim of this study was to investigate the clinical application of a high-sensitivity cardiac troponin T (hs-cTnT) test in the diagnosis of acute myocardial infarction (AMI). Serum levels of hs-cTnT and cardiac troponin I (cTnI) were detected in 240 AMI patients and 200 healthy donors and used to plot receiver operating characteristic (ROC) curves. A clinically applicable diagnostic cut-off v...

متن کامل

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2014