Indoor occupancy estimation from carbon dioxide concentration
نویسندگان
چکیده
This paper presents an indoor occupancy estimator with which we can estimate the number of real-time indoor occupants based on the carbon dioxide (CO2) measurement. The estimator is actually a dynamic model of the occupancy level. To identify the dynamic model, we propose the Feature Scaled Extreme Learning Machine (FS-ELM) algorithm, which is a variation of the standard Extreme Learning Machine (ELM) but is shown to perform better for the occupancy estimation problem. The measured CO2 concentration suffers from serious spikes. We find that pre-smoothing the CO2 data can greatly improve the estimation accuracy. In real applications, however, we cannot obtain the real-time globally smoothed CO2 data. We provide a way to use the locally smoothed CO2 data instead, which is real-time available. We introduce a new criterion, i.e. x-tolerance accuracy, to assess the occupancy estimator. The proposed occupancy estimator was tested in an office room with 24 cubicles and 11 open seats. The accuracy is up to 94 percent with a tolerance of four occupants.
منابع مشابه
Estimation of classrooms occupancy using a multi-layer perceptron
This paper presents a multi-layer perceptron model for the estimation of classrooms number of occupants from sensed indoor environmental data–relative humidity, air temperature, and carbon dioxide concentration. The modelling datasets were collected from two classrooms in the Secondary School of Pombal, Portugal. The number of occupants and occupation periods were obtained from class attendance...
متن کاملCD-HOC: Indoor Human Occupancy Counting using Carbon Dioxide Sensor Data
Human occupancy information is crucial for any modern Building Management System (BMS). Implementing pervasive sensing and leveraging Carbon Dioxide data from BMS sensor, we present Carbon Dioxide Human Occupancy Counter (CD-HOC), a novel way to estimate the number of people within a closed space from a single carbon dioxide sensor. CD-HOC de-noises and pre-processes the carbon dioxide data. We...
متن کاملPredictive model for CO2 generation and decay in building envelopes
Understanding carbon dioxide generation and decay patterns in buildings with high occupancy levels is useful to identify their indoor air quality, air change rates, percent fresh air makeup, occupancy pattern, and how a variable air volume system to off-set undesirable CO2 level can be modulated. A mathematical model governing the generation and decay of CO2 in building envelopes with forced ve...
متن کاملStudy of Dioxide Carbon Concentration and Indoor Air Quality in Some Buildings in the Equatorial Region of Cameroon (Yaounde)
Background and purpose: Elevated CO2 rate in a building affect the health of occupant. This document presents results of an experimental analysis conducted in 50 offices located in 12 buildings with different layer in Cameroon (Yaounde). This study took place in 2012, during the dry and the rainy seasons. The main goal is to show the influence of the building structure, the ventilation and the ...
متن کاملA Multi-Sensor Based Occupancy Estimation Model for Supporting Demand Driven HVAC Operations
Heating, ventilation, and air conditioning (HVAC) is a major energy consumer in buildings, and. implementing demand driven HVAC operations is a way to reduce HVAC related energy consumption. This relies on the availability of occupancy information, which determines peak/off-hour modes that impact cooling/heating loads of HVAC systems. This research proposes an occupancy estimation model that is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/1607.05962 شماره
صفحات -
تاریخ انتشار 2016