Patient comfort levels and treatment parameters in laser photocoagulation: comparison of patterned scanning versus single spot laser machines
نویسندگان
چکیده
Aims: To compare the t reatment parameters , outcomes, and patient comfort levels following patterned scanning laser photocoagulation versus single spot laser photocoagulation. Methods: This prospective randomized controlled trial involved 18 eyes of 16 patients. Patients with retinal diseases requiring laser photocoagulation to the retina were recruited and randomized to undergo laser photocoagulation using patterned scanning laser or single spot laser machines. Treatment parameters were recorded. Comfort levels and cooperation were evaluated by visual analog scales by both the patients and treating ophthalmologists. Results: There was no statistically significant difference between treatment parameters in the two groups except that the patterned scanning laser group had a shorter laser shot duration (p < 0.001). Regarding the patient comfort levels and cooperation, there were no significant differences with respect to the two machines used (p = 0.95 and 0.45, respectively). Conclusions: Patterned scanning and single spot laser photocoagulation appeared to result in similar patient comfort. The use of patterned scanning laser machine did not appear to reduce the time required for the procedure.
منابع مشابه
Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study
Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...
متن کاملTreatment of nevus spilus with CO2 Laser
Background: Nevus spilus can produce considerable disfigurement. There is no specific and successful treatment for this nevus. Objective: The purpose of this study was to evaluate the efficacy of CO2 laser in the treatment of nevus spilus. Patients and Methods: This quasi-experimental clinical trial was performed on 47 patients with spilus nevus in Al-Zahra Hospital in Isfahan. The diagnosis of...
متن کاملComparison of Efficacy and Side Effects of Multispot Lasers and Conventional Lasers for Diabetic Retinopathy Treatment
Panretinal photocoagulation (PRP) is a standard treatment for proliferative diabetic retinopathy. Conventional laser (CL) therapy is performed in one or more sessions in single spot mode. Visual disabilities have been reported after treatment with CL, including central vision loss due to macular edema and peripheral visual field loss resulting from extensive inner retinal scarring. Multispot la...
متن کاملNew Instrument SEMIAUTOMATED PATTERNED SCANNING LASER FOR RETINAL PHOTOCOAGULATION
The concept of retinal photocoagulation was introduced by Meyer-Schwickerath for the treatment of diabetic retinopathy in the 1950s and used with some success in the 1960s. The xenon arc photocoagulator utilized for this purpose was large, polychromatic, inefficient, and difficult to operate, prompting a search for a better method of treatment. Further progress was achieved when ruby,1 argon io...
متن کاملPercutaneous laser photocoagulation of osteoid osteoma: Assessment of treatment in nine cases
ABSTRACT Background: Osteoid osteoma is a benign bony neoplasm and its classic treatment is surgery. In the r ecent decades percutaneous laser therapy was suggested to be replaced by surgery. In this study we have reviewed the results of the first applications of interstitial laser photocoagulation (ILP) for treatment of osteoid osteoma in Iranian patients. Materials and Methods: In this case s...
متن کامل