Recent Experimental Results from the NA62 Gigatracker Prototypes: an Hybrid Silicon Pixel Detector with 100 ps Time Resolution

نویسنده

  • Sara Garbolino
چکیده

G. Aglieri Rinellaa,V. Carassitic,A. Ceccuccia,E. Cortinad ,J. Daguina,G. Dellacasab,M. Fiorinia,P. Jarrona,J. Kaplona,A. Klugea,F. Marchettoa,E. Martind ,A. Mapellia, f ,G. Mazzab,M. Morela,M. Noya,G. Nüssled ,P. Petagnaa,L. Perktolda,F. Petruccic,e,A. Cotta Ramusinoc,P. Riedlera,A. Rivettib,R. Wheadonb aCERN, Geneva Switzerland,bINFN Torino, Italy,cINFN Ferrare, Italy,dUCL Louvain la Neuve, Belgium, eUniversity of Ferrara, f EPFL Lausanne, Switzerland

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Readout Electronics of the Na62 Gigatracker System

A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these req...

متن کامل

An ultra fast silicon pixel detector for the NA 62 experiment : the Gigatracker

The beam spectrometer of the NA62 experiment has to sustain high and non-uniform beam rate (∼1.5 MHz/mm 2 in the hot center and 0.8-1.0 GHz in total, hence the name Gigatracker) and should preserve beam divergence and limit beam hadronic interactions. The Gigatracker has to provide precise momentum, time and angular measurements on every single track of the secondary 75 GeV/c hadron beam with a...

متن کامل

Microfluidic cooling for detectors and electronics

Micro-channel cooling is gaining considerable attention as an alternative technique for cooling of high energy physics detectors and front-end electronics. This technology is being evaluated for future tracking devices, where material budget limitations are a major concern. It is currently under investigation as an option for the cooling of the NA62 Gigatracker silicon pixel detector, where a m...

متن کامل

Kaon identification in the NA62 experiment at CERN

The main purpose of the NA62 experiment at the CERN SPS is to measure the Branching Ratio of the ultra-rare kaon decay K+ → π+νν̄ with 10% accuracy. This will be achieved by collecting about 100 events with a Signal to Background ratio of 10/1. NA62 will use a 75 GeV/c unseparated charged hadron beam and a kaon decay-in-flight technique. For the kaon identification a hydrogen gas-filled differen...

متن کامل

5 v 1 2 1 N ov 2 00 0 Beam Test of BTeV Pixel Detectors

The silicon pixel vertex detector is one of the key elements of the BTeV spectrometer. Detector prototypes were tested in a beam at Fermilab. We report here on the measured spatial resolution as a function of the incident angles for different sensorreadout electronics combinations. We compare the results with predictions from our Monte Carlo simulation.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011