Performance of a GSO Brain PET Camera

نویسندگان

  • M. E. Daube-Witherspoon
  • C. Cardi
چکیده

A high sensitivity, high resolution brain PET scanner has been developed. The scanner comprises 58 rows of 320 4 x 4 x I O mm3 gadolinium orthosilicate (GSO) crystals, coupled to a continuous light guide that is sampled by 288 39-mm photomultiplier tubes in a hexagonal grid. A distortion removal algorithm has been developed to remove position non-linearities and to identify individual crystal regions in a flood image with physical crystal locations on the scanner. A central profile through a sinogram of a point source in the center of the scanner shows that the spatial resolution (fwhm) is 3.5 mm (fwtm=8.4 mm). The Hoffman brain phantom has been successfully imaged to demonstrate the capability of the scanner. Table 1 Comparison of physical properties of NaI(TI), LSO and GSO scintillators. The decay time given for GSO corresponds to a Cerium concentration of 0.5% moles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An overview of clinical PET/CT

This article is intended to provide an overview of various aspects of clinical PET/CT. These include discussions of: (i) Important areas of clinical application; (ii) Opportunities in clinical research; (iii) Scanner and operating-mode considerations (e.g. BGO vs. LSO, LYSO or GSO scanners, 2D vs. 3D imaging). (iv) Study-specific considerations (e.g. patient preparation and positioning is...

متن کامل

Performance of a brain PET camera based on anger-logic gadolinium oxyorthosilicate detectors.

UNLABELLED A high-sensitivity, high-resolution brain PET scanner ("G-PET") has been developed. This scanner is similar in geometry to a previous brain scanner developed at the University of Pennsylvania, the HEAD Penn-PET, but the detector technology and electronics have been improved to achieve enhanced performance. METHODS This scanner has a detector ring diameter of 42.0 cm with a patient ...

متن کامل

Performance characteristics of a new 3-dimensional continuous-emission and spiral-transmission high-sensitivity and high-resolution PET camera evaluated with the NEMA NU 2-2001 standard.

UNLABELLED The SET-3000 G/X (clinical tomograph with high resolution and a large axial field of view) is a 3-dimensional (3D) (only) dedicated PET camera with germanium oxyorthosilicate (GSO) and bismuth germanate (BGO) scintillators. The main characteristic of the SET-3000 G/X PET scanner is 3D continuous-emission and spiral-transmission (CEST) scanning, yielding a reduction in whole-body scan...

متن کامل

Development of Large area Gamma-ray Camera with GSO(Ce) Scintillator Arrays and PSPMTs

We have developed a position-sensitive scintillation camera with a large area absorber for use as an advanced Compton gamma-ray camera. At first we tested GSO(Ce) crystals. We compared light output from the GSO(Ce) crystals under various conditions: the method of surface polishing, the concentration of Ce, and co-doping Zr. As a result, we chose the GSO(Ce) crystals doped with only 0.5 mol% Ce,...

متن کامل

Clinical PET imaging with the C-PET camera.

OBJECTIVE Clinical PET studies require a high-performance and user-friendly PET camera. The C-PET camera uses a simple design and a large field of view for these purposes. METHODS We describe the camera features, daily quality control, and routine clinical study preparation, performance, processing and presentation from the technologist's perspective. RESULTS The C-PET camera is used for wh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009