Dosimetry of a new P-32 ophthalmic applicator.
نویسندگان
چکیده
PURPOSE The potential of P-32 ophthalmic applicator irradiation after pterygium excision has been demonstrated as an alternative to Sr∕Y-90 irradiation. This study aimed to provide the clinical dosimetry for this new applicator. METHODS The prototype of a cylindrical P-32 applicator was fabricated according to the Monte Carlo (MC)-based design study. At a nominal activity of 6 mCi (0.22 GBq), the absorbed dose rate at the front surface (i.e., reference dose rate) was measured by using an extrapolation ionization chamber (EC). The radiochromic film (RCF) was also used to measure the reference dose, axial depth dose distributions and transaxial dose profiles at various depths in water. RESULTS The reference dose rate was 3.89 ± 0.14 cGy∕s for EC and 3.84 ± 0.25 cGy∕s for RCF. The depth dose rate was reduced approximately by an order of magnitude for every 2 mm depth in water. Measured depth doses in depths of 0.5-2.5 mm agreed with Monte Carlo data within ±3%. Due to nonuniform absorption of P-32 into an absorbent disk, the dose profiles were not symmetric and decreased more rapidly toward the periphery than those predicted by the MC. The authors confirmed no leakage of P-32 activities and negligible exposure rate around the hand grip of the applicator. CONCLUSIONS The P-32 applicator can deliver therapeutic doses to the surface of the conjunctiva, while sparing the lens better than Sr∕Y-90 applicators. The doses at any points from the P-32 applicator could be calculated by using the measured dosimetry data. They also confirmed no leakage of the source, reliable integrity of the applicator, and negligible exposure level around the hand grip of the applicator. However, due to a possibility of nonuniform distributions of P-32 in an absorbent disk, measuring dose profiles as well as the reference dose rate for every new applicator would be recommended.
منابع مشابه
Application of the thermoluminescent technique for calibration and dosimetry of 90 Sr + 90 Y applicators
Dermatological and ophthalmic applicators are used in brachytherapy for the treatment of superficial lesions of skin and eyes. The calibration of these applicators should be realized periodically, according to quality control programs and international recommendations about dosimetry and calibration of brachytherapy sources. Thin thermoluminescent dosimeters of CaSO4:Dy were utilized in this wo...
متن کاملComparison of Electron-Beam Dose Distributions in a Heterogeneous Phantom Obtained Using Radiochromic Film Dosimetry and Monte Carlo Simulation
Introduction: Nowadays new radiochromic films have an essential role in radiotherapy dosimetry. Properties such as high sensitivity, good reproducibility, high spatial resolution, easy readout and portability have made them attractive for dosimetry, especially in high-dose-gradient regions. Material and Methods: In this study, electron-beam dose distributions in homogenous and heterogeneous pha...
متن کاملMonte Carlo Simulation of Two Ru Eye Plaques in a New Mathematical Human Eye Model
BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of Ru, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description...
متن کاملDosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques
Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 38 11 شماره
صفحات -
تاریخ انتشار 2011