[Preliminary results of a wide-angle corneal topography system for Placido-based videokeratographers].

نویسنده

  • Luis Alberto Vieira de Carvalho
چکیده

PURPOSE To develop the instrumentation and software for wide-angle corneal topography using a Placido-based videokeratographer. The objective is to allow the measurement of a greater area of the cornea using a simple adaptation to the Placido mire. METHODS Using the traditional Placido disc of a commercial corneal topographer, 9 LEDs (Light Emitting Diodes) were installed on the conic mire so that the voluntary patient could gaze in different directions. For each direction Placido images were acquired and processed to form, using a sophisticated computer graphics algorithm, a tridimensional map of the whole cornea. RESULTS It was shown that up to 100% more area of the cornea may be mapped using the here described technique. We present results for a spherical surface calibration and also for a highly astigmatic cornea and analyze quantitatively the additional area that is recovered in terms of curvature and true elevation. CONCLUSIONS We believe that this new technique opens opportunities for the improvement of other applications which might benefit from this additional information, such as: contact lens adaptation and design improvement, algorithms for customized refractive surgery, among others.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Forward ray tracing for image projection prediction and surface reconstruction in the evaluation of corneal topography systems.

A forward ray tracing (FRT) model is presented to determine the exact image projection in a general corneal topography system. Consequently, the skew ray error in Placido-based topography is demonstrated. A quantitative analysis comparing FRT-based algorithms and Placido-based algorithms in reconstructing the front surface of the cornea shows that arc step algorithms are more sensitive to noise...

متن کامل

Corneal Topography: A review, new ANSI standards and problems to solve

This review of corneal topography has three sections: 1. a brief introduction to how corneal topography instruments work. A quantitative comparison of the relative accuracy of slope based and position based instruments is presented. 2. a summary of and commentary on the newly issued ANSI standards for corneal topography. 3. an examination of problems still facing corneal topography. OCIS codes:...

متن کامل

Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device

PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...

متن کامل

Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation

PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...

متن کامل

Comparison of Topographic Technologies in Anterior Surface Mapping of Keratoconus using Two Display Algorithms and Six Corneal Topography Devices

Purpose: To evaluate anterior surface topographic technologies and display algorithms in mapping keratoconus. Materials and methods: A total of 27 eyes of 17 subjects clinically diagnosed with keratoconus were imaged on six topographers: EyeSys, Alcon EyeMap, Keratron, TMS-1, Orbscan and PAR corneal topography system. Axial distance (AD) and instantaneous radius of curvature (IROC) algorithms w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 2008