Balloon-based adjuvant radiotherapy in breast cancer: comparison between (99m)Tc and HDR (192)Ir.
نویسندگان
چکیده
OBJECTIVE To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with (99m)Tc and balloon brachytherapy with high-dose-rate (HDR) (192)Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. MATERIALS AND METHODS Simulations of implants with (99m)Tc-filled and HDR (192)Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. RESULTS The (99m)Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h(-1).mCi(-1) and 0.190 cGyh(-1).mCi(-1) at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh(-1).mCi(-1), respectively, for the HDR (192)Ir balloon. An exposure time of 24 hours was required for the (99m)Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR (192)Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. CONCLUSION Temporary (99m)Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR (192)Ir balloon implantation, which is the current standard in clinical practice.
منابع مشابه
Electronic brachytherapy as adjuvant therapy for early stage breast cancer: a retrospective analysis
PURPOSE This multicenter, retrospective study evaluated treatment and clinical outcomes of patients with early stage breast cancer who received adjuvant high-dose rate (HDR) electronic brachytherapy (EBT) treatment post-lumpectomy using the Axxent(®) EBT system. Dosimetric data from the EBT treatment plans were compared with those based on iridium-192 HDR brachytherapy. MATERIAL AND METHODS M...
متن کاملConsideration of accurate dose distribution for Contura balloon catheter in breast brachytherapy with MCNP5 simulation
Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...
متن کاملComparison of tumor and normal tissue dose for accelerated partial breast irradiation using an electronic brachytherapy eBx source and an Iridium‐192 source
The objective of this study has been to compare treatment plans for patients treated with electronic brachytherapy (eBx) using the Axxent System as adjuvant therapy for early stage breast cancer with treatment plans prepared from the same CT image sets using an Ir-192 source. Patients were implanted with an appropriately sized Axxent balloon applicator based on tumor cavity size and shape. A CT...
متن کاملAcute Skin and Pharynx Complications Following Adjuvant Hypofractionated Versus Conventional Radiotherapy in Patients with Breast Cancer
Background: Hypofractionated radiotherapy (HF) method was introduced to overcome the quickly growing tumor cells as well as shortening whole treatment course in solid tumors such as breast cancers. Here, we compared the incidence of dermatitis and pharyngitis among patients undergoing HF versus conventional fractionationated (CF) radiation therapy following surgery for breast cancer. Methods: ...
متن کاملMonte Carlo investigation on precise dosimetry of HDR breast brachytherapy with Accuboost
Introduction: Accuboost is a HDR brachytherapy system in early stages breast cancer treatment. This device provides a completely noninvasive procedure with parallel-opposed radiation from two immobilizing peripheral applicators that caused it a preferred option of modalities to choose. In most commercial treatment planning systems, tissues are considered as a simple water phan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiologia brasileira
دوره 49 2 شماره
صفحات -
تاریخ انتشار 2016