Calcification of porcine prosthetic heart valves: a radiographic and light microscopy study.

نویسندگان

  • P R Cipriano
  • M E Billingham
  • P E Oyer
  • L M Kutsche
  • E B Stinson
چکیده

To determine the incidence and extent of calcification of implanted glutaraldehyde-treated porcine prosthetic heart valves, 82 valves explanted from 73 patients were examined for calcium by radiography and light microscopy. At the time of valve implantation, the patients were 2 1/4-76 years old. The included 15 children (patients younger than 15 years of age, mean age at time of valve implantation 8.7 +/- 4.1 years) and 58 adults (patients older than 15 years, mean age at time of valve implantation 53.5 +/- 15.1 years). Valves explanted from children (average time implanted 4.6 +/- 1.7 years) included four aortic, five mitral, as well as six right ventricle-pulmonary artery conduits and one left ventricle-abdominal aorta conduit. Valves explanted from adults (average time implanted 3.2 +/- 2.5 years) included 32 aortic and 32 mitral, as well as one tricuspid valve and one valve from a right ventricle-pulmonary artery conduit. Calcification of explanted valves was graded from 0 to 4+ based on radiographs. All 16 valves from children were calcified, with grade 3+ or 4+ calcification in each of the aortic and mitral valves. In adult patients, calcification was present in 10 of 33 valves (30%) implanted for less than 3 years (average time implanted 1.0 year), in nine of 11 valves (82%) implanted for 3-5 years (average time implanted 3.7 years) and in 21 of 22 valves (96%) implanted for 5 years or longer (average time implanted 6.2 years). Analysis of variance demonstrated that calcification was strongly related to the duration that valves were implanted (p less than 0.001). Age at the time of valve implantation also had a strong effect (p less than 0.001) on the amount of valvular calcium. Valves from children showed the most calcification, and the amount did not change when valves were implanted in patients 30 years of age or older. Patient sex and valve position had no effect on the amount of calcification. Calcification occurred at each right- and left-heart valve position, most frequently at sites of commissural attachments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calcification of Porcine Prosthetic Heart Valves: A Radiographic and Light Microscopic Study

To determine the incidence and extent of calcification of implanted glutaraldehyde-treated porcine prosthetic heart valves, 82 valves explanted from 73 patients were examined for calcium by radiography and light microscopy. At the time of valve implantation, the patients were 21⁄4/4-76 years old. They included 15 children (patients younger than 15 years of age, mean age at time of valve implant...

متن کامل

Chemically determined mineral content of explanted porcine aortic valve bioprostheses: correlation with radiographic assessment of calcification and clinical data.

Bioprosthetic valve calcification is usually assessed pathologically by gross inspection, radiographic studies, and histologic examination. Quantitation of mineral content by chemical assay has not been reported for failed clinical valves removed from adults. In this study, calcium determination by atomic absorption spectroscopy was done on 52 removed porcine valves after routine pathologic exa...

متن کامل

Marked thrombosis and calcification of porcine heterograft valves.

Prosthetic valvular dysfunction resulting in clinically significant complications occurred in six patients with Hancock porcine heterografts. In one patient with a prosthetic valve in the aortic position, massive prosthetic thrombosis resulted in sudden death. In two patients who had a mitral prosthesis, thrombosis resulted in congestive heart failure and systemic embolization; in one of the la...

متن کامل

Results of a decellularized porcine heart valve implanted into the juvenile sheep model.

OBJECTIVE This study was performed to evaluate the possibility of creating a glutaraldehyde-free porcine xenograft to improve long-term durability. METHODS A decellularized porcine pulmonary valve was implanted into the right ventricular outflow tract of 7 juvenile sheep. Valves were explanted after 3 months (n = 4) and 6 months (n = 3). Evaluation was performed by gross examination, radiogra...

متن کامل

Degenerative processes in bioprosthetic mitral valves in juvenile pigs

BACKGROUND Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthet...

متن کامل