Clinical outcomes with use of erythropoiesis stimulating agents in patients with the HeartMate II left ventricular assist device.

نویسندگان

  • Michael E Nassif
  • Jayendrakumar S Patel
  • Jerrica E Shuster
  • David S Raymer
  • Ronald Jackups
  • Eric Novak
  • Brian F Gage
  • Sunil Prasad
  • Scott C Silvestry
  • Gregory A Ewald
  • Shane J LaRue
چکیده

OBJECTIVES This study evaluated clinical outcomes associated with erythropoiesis stimulating agent (ESA) use in left ventricular assist devices (LVAD)-supported patients. BACKGROUND Use of ESAs in patients with LVADs may minimize blood transfusions and decrease allosensitization. ESAs increase thrombotic events, which is concerning because LVADs are sensitive to pump thrombosis (PT). METHODS We retrospectively reviewed 221 patients at our center who received a HeartMate II (Thoratec Corp., Pleasanton, California) LVAD between January 1, 2009 and June 6, 2013. Patients were divided into those who received ESAs during index admission (n = 121) and those who did not (n = 100). Suspected PT was defined as evidence of thrombus in the LVAD or severe hemolysis (lactate dehydrogenase >1,000 mg/dl or plasma-free hemoglobin >40 mg/dl). Outcomes were compared between cohorts using inverse probability-weighted analyses. RESULTS During a mean follow-up of 14.2 ± 11.9 months, suspected PT occurred in 37 patients (ESA 23%, no ESA 12%; p =0.03). The ESA cohort received ESAs 13.9 ± 60.9 days after LVAD implantation. At 180 days, event-free rates for suspected PT were ESA 78.6% versus no ESA 94.5% (p < 0.001). ESA use had higher rates of suspected PT (hazard ratio [HR]: 2.35; 95% confidence interval [CI]: 1.38 to 4.00; p = 0.002). For every 100-unit increase in cumulative ESA dosage, the hazard of suspected PT increased by 10% (HR: 1.10; 95% CI: 1.04 to 1.16; p < 0.001). After inverse probability weighting, ESA use was associated with a significantly higher rate of all-cause mortality (HR: 1.62; 95% CI: 1.12 to 2.33; p = 0.01). CONCLUSIONS ESA use in LVAD patients is associated with higher rates of suspected PT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Survival after left ventricular assist device with and without temporary right ventricular support.

BACKGROUND Right ventricular (RV) failure after the insertion of a left ventricular assist device (LVAD) historically results in poor outcomes. Patients requiring temporary RV support after LVAD insertion are a heterogeneous group of patients consisting of those in cardiogenic shock after myocardial infarction, to those with chronic decompensated heart failure. For patients requiring biventricu...

متن کامل

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.

OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...

متن کامل

Initial clinical experience with the HeartMate II axial-flow left ventricular assist device.

The redesigned HeartMate II, an axial-flow left ventricular assist device, is simpler, smaller, and easier to operate than are pulsatile pumps. These design characteristics should make the HeartMate II more reliable and durable and broaden the eligible population base. We implanted the HeartMate II in 43 patients (average age, 42 yr). The indication for use was bridge-to-heart transplantation i...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Heart failure

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2015