A new variant of scaphoid reconstruction: Treatment of scaphoid non-union with avascular bone interponate and high compression screw (Synthes®)

نویسندگان

  • Christian Eder
  • Nina Schwab
  • Ariane Scheller
  • Björn Dirk Krapohl
چکیده

Scaphoid fractures as frequently overseen injuries often result in scaphoid non-unions, that need to be treated to prevent carpal collapse and secondary cartilage damage. Vital bone tissue and compression of fracture and bone graft ends seem to be crucial in for ossification and final bone healing. In the present study we compare our results using a high compression screw (HCS Synthes(®)) to results in the literature using different kinds of internal fixation including compression screws of various types. We present 22 patients with scaphoid non-unions treated with a bone graft and a HCS Synthes(®). We evaluated our post-operative results. The Manchester-Modified Disability of the Shoulder, Arm and Hand-Score (M-Dash) imposed with an average of 29.8 points (MD=29 / SD=9.46 / MIN=18 / MAX=48). None of the re-evaluated patients sorrowed for pain in rest. Five patients stated pain (ranging from 4 to 8 on numeric analogue scale) after heavy burden (e.g. boxing, weight lifting).In exploring the range of motion of the operated hand we deliver the following results: dorsal extension: average 72.73° (MD=80° / SD=17.23° / MIN=30° / MAX=85°), flexion: average 73.64° (MD=80° / SD=8.97° / MIN=60° / MAX=80°), ulnar deviation: average 39.09°, (MD=40° / SD=2.02° / MIN=35° / MAX=40°), radial deviation: average 29.09°, (MD=30° / SD=3.01° / MIN=20° / MAX=30°). Additionally a performance testing was conducted: fist clenching sign: complete without pain in 100%, pinch grip: complete in 100%, moderate pain in n=1 (8.33%), opposition digitus manus I-V complete in 100%, moderate pain n=2 (16.67%). Three patients with persisting fracture gap had a scaphoid bone fractured in the proximal third; one patient even with a very small proximal fragment. One persisting non-union was localized in the middle third (period between injury and operation = 5 years). In conclusion, our patients showed better healing rates compared to results presented in the literature. Non-unions localized in the proximal third of the scaphoid did not seem to benefit using this technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The comparison of results for the bone grafting in treatment of scaphoid non:union: with and without avascular necrosis

 Abstract Background: The varieties of treatment methods for the scaphoid non:::union::: have always been a discussable issue for orthopaedic surgeons. The current study, considered to be review for treatment results of the patients who sustained the scaphoid non:::union::: with or without avascular necrosis and compared these two groups clinically and radiologically. Methods: The clinical and ...

متن کامل

A comparison of two headless compression screws for operative treatment of scaphoid fractures

PURPOSE The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw. METHODS Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contr...

متن کامل

Treatment of scaphoid waist fractures with the HCS screw

The aim of the study was to evaluate the clinical results of the Headless Compression Screw (HCS, Synthes) when used for treatment of acute scaphoid waist fractures. The new screw design generates interfragmentary compression with use of a compression sleeve. Twenty-one patients were treated for acute scaphoid waist fractures type B2 with HCS screws. The average time to the final follow-up exam...

متن کامل

Scaphoid fractures with unusual presentations: a case series

Despite the high incidence of scaphoid fractures, their diagnosis and treatment is often delayed which can lead to complications such as non-union, avascular necrosis, and future arthritis. We present three cases with non-classical mechanisms of injury, leading to a delayed diagnosis in all three cases. Our cases serve to emphasize the importance of a high index of suspicion for the possibility...

متن کامل

Hybrid Russe Procedure for Scaphoid Waist Fracture Nonunion With Deformity.

PURPOSE To assess the results of a hybrid Russe procedure using a corticocancellous strut, cancellous autologous nonvascularized bone graft, and cannulated headless compression screw to reduce the deformity reliably from a collapsed scaphoid nonunion, provide osteoinductive stimulus, and stabilize the fracture for predictable union. METHODS A hybrid Russe procedure was performed for scaphoid ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2015