Comparing sensitivity and specificity methods of chemical and baronet affinity measuring glycated hemoglobin with HPLC method

نویسنده

  • Hamidreza Joshaghani
چکیده

Introduction: Glycated hemoglobin level is a good estimate of the average blood glucose over a period. Therefore, the measurement accuracy is very important. The most commonly available methods for measuring HbA1C are chemistry, immunoassay, enzymatic, electrophoresis, baronet affinity and HPLC. There is still no standard way that all the laboratories do it. The aim of this study was to compare two methods of chemical and baronet affinity with HPLC method for the verification accuracy. Methods: This experimental study was done on 50 samples. Glycosylated hemoglobin test performed by the baronet affinity method by Nycocard, HPLC by Bio Rad D-10 and chemical methods by Mahsa Yaran kit. Results: By HPLC, 21 samples (42%) were normal, 4 cases (8%) were moderate and 25 (50%) were high. The mean and standard deviation and the range of HbA1C of baronet affinity, chemical and HPLC methods were 7.1±1.9 (4.4 to 10.9), 6.9±1.7 (4 to 10,6), and 8.3±2.4 (4.7 to 14.3), respectively. The sensitivity of the baronet affinity method in comparison with HPLC method was 100% and specificity was 58.6%. The sensitivity of chemical method in comparison with HPLC method was 100% and specificity was 62.1%. The correlation coefficient for both was obtained 0.633 which is statistically significant (P<0.0001). Also correlation coefficient for two methods of baronet affinity and chemical was determined 0.852, which is statistically significant. American Journal of Research Communication www.usa-journals.com Malekmahmoodi, et al., 2013: Vol 1(11) [email protected] 351 Conclusions: In this study was observed that between the two methods baronet and chemical there is a coefficient of agreement of 86,9% and even the chemical method has more specifity. Also considering the cost of this method, chemical method can be considered as a suitable method for measuring Glycosylated hemoglobin. But maybe the long-time of doing chemical method is one of the serious limitations of the laboratories to select this method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of glycohemoglobin determinations in the clinical laboratory: three years of experience.

Measurement of glycohemoglobin has been recommended for the long-term assessment of glycemic control in diabetic patients. Because different analytical methods measure different glycohemoglobin species, it has been difficult to compare results between laboratories. Here we report 3 years of experience with calibration of an affinity chromatography method for measuring total glycohemoglobin (GHb...

متن کامل

Electrospray mass spectrometry for measurement of glycohemoglobin.

With the publication of the results of the landmark 9-year Diabetes Control and Complications Trial (DCCT), the importance of Hb A1c/glycohemoglobin testing in diabetes was firmly established. The DCCT showed, at least in patients with insulin-dependent diabetes mellitus, that the risk for development and progression of the chronic complications of diabetes is closely related to the degree of m...

متن کامل

The validation of one halitosis measuring device (Etiquette checker)‎

BACKGROUND AND AIM: Various measurement devices are available for detection of halitosis. For epidemiologic studies, it is necessary to use a portable and small device. This study aimed to investigation of correlation between measuring the device (Etiquette checker) with Halimeter. METHODS: One hundred volunteers (students and patients) participated in this study. The amount of volatile sulfur ...

متن کامل

CE-HPLC Testing of Hemoglobin A1c for Assessment of Long Term Glycemic Control in Patients with Diabetes Mellitus

Glycated hemoglobin A1c (HbA1c) is routinely used in the diagnosis of diabetes mellitus (DM) and for monitoring the long-term glycemic control in patients already diagnosed with DM. HbA1c is measured in the clinical laboratory based either on the charge of the glycated molecule by cation exchange high performance liquid chromatography (CE-HPLC) or electrophoresis, or on the physical structure o...

متن کامل

Hemoglobin variants and hemoglobin A1c analysis: problem solved?

Measurement of glycohemoglobin (GHb) is an integral component of the management of patients with diabetes mellitus (1, 2). Glycation is the nonenzymatic addition of a sugar residue to amino groups of proteins. Numerous proteins in the body are glycated, but GHb in blood is the analyte most widely used clinically to monitor glycemic control. The concentration of GHb is directly proportional to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013