Reference Clinical Database for Fixation Stability Metrics in Normal Subjects Measured with the MAIA Microperimeter

نویسندگان

  • Marco U. Morales
  • Saker Saker
  • Craig Wilde
  • Carlo Pellizzari
  • Aristophanes Pallikaris
  • Neil Notaroberto
  • Martin Rubinstein
  • Chiara Rui
  • Paolo Limoli
  • Michael K. Smolek
  • Winfried M. Amoaku
چکیده

PURPOSE The purpose of this study was to establish a normal reference database for fixation stability measured with the bivariate contour ellipse area (BCEA) in the Macular Integrity Assessment (MAIA) microperimeter. METHODS Subjects were 358 healthy volunteers who had the MAIA examination. Fixation stability was assessed using two BCEA fixation indices (63% and 95% proportional values) and the percentage of fixation points within 1° and 2° from the fovea (P1 and P2). Statistical analysis was performed with linear regression and Pearson's product moment correlation coefficient. RESULTS Average areas of 0.80 deg2 (min = 0.03, max = 3.90, SD = 0.68) for the index BCEA@63% and 2.40 deg2 (min = 0.20, max = 11.70, SD = 2.04) for the index BCEA@95% were found. The average values of P1 and P2 were 95% (min = 76, max = 100, SD = 5.31) and 99% (min = 91, max = 100, SD = 1.42), respectively. The Pearson's product moment test showed an almost perfect correlation index, r = 0.999, between BCEA@63% and BCEA@95%. Index P1 showed a very strong correlation with BCEA@63%, r = -0.924, as well as with BCEA@95%, r = -0.925. Index P2 demonstrated a slightly lower correlation with both BCEA@63% and BCEA@95%, r = -0.874 and -0.875, respectively. CONCLUSIONS The single parameter of the BCEA@95% may be taken as accurately reporting fixation stability and serves as a reference database of normal subjects with a cutoff area of 2.40 ± 2.04 deg2 in MAIA microperimeter. TRANSLATIONAL RELEVANCE Fixation stability can be measured with different indices. This study originates reference fixation values for the MAIA using a single fixation index.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal specific measurement of dark-adapted visual function: validation of a modified microperimeter

BACKGROUND Scotopic function is an important marker of many retinal diseases and is increasingly used as an outcome measure in clinical trials, such as those investigating gene therapy for Lebers congenital amaurosis. Scotopic visual function has traditionally been measured using an adapted perimetry system such as the Humphrey field analyser (HFA). However this system does not control for fixa...

متن کامل

Retinal specific measurement of dark-adapted visual function: A validation study

Background: Scotopic function is an important marker of many retinal diseases and is increasingly used as an outcome measure in clinical trials, such as those investigating gene therapy for Lebers congenital amaurosis. Scotopic visual function has traditionally been measured using an adapted perimetry system such as the Humphrey field analyser (HFA). However this system does not control for fix...

متن کامل

Fixation stability, fixation location, and visual acuity after successful macular hole surgery.

PURPOSE This study examined whether changes in fixation stability and fixation location are good predictors of visual acuity after successful macular hole surgery. METHODS Ten patients with macular hole were tested before surgery and at 1 and 3 months after surgery. Visual acuity was measured with the ETDRS; fixation stability and fixation location were assessed with the MP-1 Microperimeter (...

متن کامل

Fixation stability measurement using the MP1 microperimeter.

PURPOSE The Nidek microperimeter (MP1, Nidek Instruments, Italy) is a microperimetry device that also assesses fixation stability. The MP1 does not use the method of quantifying fixation stability by calculating a bivariate contour ellipse area (BCEA). Here we compare the MP1 fixation quantification with the BCEA technique by correlating these values to various parameters of reading known to be...

متن کامل

Task-specific fixation behavior in macular disease.

PURPOSE Persons with central scotomas frequently use a preferred retinal locus (PRL) in place of the damaged fovea to fixate a target. Here the authors use a novel statistical technique to determine whether the retinal locus used for fixating a point target is the same as that used for reading words. METHODS Nine subjects with established macular disease and bilateral central scotomas were re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016