Relationship Between Near-Infrared Spectroscopy and Transabdominal Ultrasonography: Noninvasive Monitoring of Intestinal Function in Neonates

نویسندگان

  • Devang H. Akotia
  • Jayson T. Durham
  • Kathy M. Arnell
  • Deborah L. Petruzelli
  • Anup C. Katheria
چکیده

BACKGROUND Near-infrared spectroscopy (NIRS) has the potential to continuously and noninvasively monitor intestinal function. This technology may be valuable because among neonates, intestinal maturity is highly variable and difficult to assess based solely on clinical signs. The aim of this study was to determine if there is an association between NIRS-based StO2 measurements and peristaltic activity assessed by transabdominal ultrasonography (US). MATERIAL/METHODS Nineteen neonates of gestational age >32 weeks were categorized according to "no/low" versus "normal/hyperactive" motility levels, based on blinded US scan results. StO2 was recorded every 2 s for 24 h, following the ultrasound recording. Differences between the resulting estimates of average StO2 (bias of fits) and goodness-of-fit (residuals) were evaluated. RESULTS Newborns with normal/hyperactive motility had higher mean StO2 than newborns with no/low motility (72.3±4.4 vs. 65.5±7.9, p<0.05, F=5.65). Residual errors were not significantly different between the 2 groups (p=0.213, F=0.213). A multivariate linear regression model using the means, residuals, and pairwise products of both, demonstrated more significant separation (0.47±0.26 vs. -0.24±0.33, p<0.01, F=27.4). A non-linear variant of the multivariate linear regression model demonstrated greatest separation (0.68±0.24 vs. -0.49±0.53, p<0.01, F=41.9). CONCLUSIONS This is the first study to demonstrate an association between NIRS-based StO2 measurements and peristaltic activity visualized by ultrasound imaging. NIRS may offer a continuous, noninvasive method to assess motility. This may have significant implications in premature infants at risk for feeding intolerance or necrotizing enterocolitis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Transabdominal and Transrectal Ultrasonography of the Prostate Gland in Dogs

Objective- To compare transabdominal (TA) and transrectal (TR) ultrasonography of the prostate gland. Design- Experimental study. Animals- 10 intact male dogs that required euthanasia for reasons other than prostatic disease. Procedures- Prostatic length (L), width (W) and height (H) were measured in T A (L1, W1 and H1) and TR (L2 and H2...

متن کامل

Near-Infrared Spectroscopy for Objectifying Cerebral Effects of Laser Acupuncture in Term and Preterm Neonates

Laser acupuncture (LA) becomes more and more relevant in neonates and infants. With near-infrared spectroscopy (NIRS), a continuous and noninvasive measurement of tissue oxygenation is possible. Aim was to investigate, whether the application of LA was associated with any changes in regional cerebral oxygen saturation (rcSO2) in term and preterm neonates. The study included 20 neonates (12 male...

متن کامل

Near-infrared spectroscopy: applications in neonates.

Near-infrared spectroscopy (NIRS) offers non-invasive, in-vivo, real-time monitoring of tissue oxygenation. Changes in regional tissue oxygenation as detected by NIRS may reflect the delicate balance between oxygen delivery and consumption. Originally used predominantly to assess cerebral oxygenation and perfusion perioperatively during cardiac and neurosurgery, and following head trauma, NIRS ...

متن کامل

Noninvasive cerebral perfusion imaging in high-risk neonates.

Advances in medical and surgical care of the high-risk neonate have led to increased survival. A significant number of these neonates suffer from neurodevelopmental delays and failure in school. The focus of clinical research has shifted to understanding events contributing to neurological morbidity in these patients. Assessing changes in cerebral oxygenation and regulation of cerebral blood fl...

متن کامل

Merits and pitfalls of multimodality brain monitoring.

In 1841 Magendi pioneered to measure cerebrospinal fluid pressure using the ‘‘sphygmometer,’’ an instrument originally designed for assessment of blood pressure. From then on, it took 110 years before the first intracranial pressure (ICP) monitoring data has been published in 1951, first ever introducing the important key-word of ‘‘monitoring’’ in the context of the human brain [1]. From this m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2016