Accuracy and limitations of continuous glucose monitoring using spectroscopy in critically ill patients

نویسندگان

  • Roosmarijn TM van Hooijdonk
  • Tineke Winters
  • Johan C Fischer
  • Edmée C van Dongen-Lases
  • James S Krinsley
  • Jean-Charles Preiser
  • Marcus J Schultz
چکیده

BACKGROUND OptiScanner devices, continuous glucose monitoring devices that perform automated blood draws via a central venous catheter and create plasma through centrifugation, measure plasma glucose levels through mid-infrared spectroscopy at the bedside. The objective of this study was to determine accuracy and practicality of the devices in critically ill patients attempting glycemic control. METHODS The plasma glucose level was measured by the devices and in comparative plasma samples using Yellow Springs Instrument (YSI) plasma analyzers. After adding several previously unrecognized interferences in the interference library, we reanalyzed the mid-infrared signals and compared the resulting plasma glucose level with the reference value. Results are presented in Clarke error grids, glucose prediction errors and Bland-Altman plots and expressed as correlation coefficients. RESULTS We analyzed 463 comparative samples from 71 patients (median 6 (4 to 9) samples per patient). After calibrating the system, a Clarke error grid showed 100% of the values in zones A or B. The glucose predictor error demonstrated that 86% of the glucose values < 75 mg/dL were within ± 15 mg/dL of the YSI results and 95% ≥ 75 mg/dL were within 20% of the comparative YSI results. Bland-Altman plot showed a bias of -0.6 with limit of agreement of -24.6 to 23.3. The Pearson correlation coefficient was 0.93 and R2 was 0.87. In one third of the patients the devices had to be disconnected prematurely (that is before planned disconnection) because of repeated occlusion alarms suggesting blood draw errors. CONCLUSION The devices needed calibration for several previously unrecognized interferences. Thereafter, accuracy of the device to measure plasma glucose levels in 'our cohort' of critically ill patients improved, but external validation is highly recommended. The automated blood draw system of the devices needs further improvement to make this device of value for clinical use (trial registration (Netherlands Trial Register): NTR2864).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Clinical Benefits and Accuracy of Continuous Glucose Monitoring Systems in Critically Ill Patients—A Systematic Scoping Review

Continuous Glucose Monitoring (CGM) systems could improve glycemic control in critically ill patients. We aimed to identify the evidence on the clinical benefits and accuracy of CGM systems in these patients. For this, we performed a systematic search in Ovid MEDLINE, from inception to 26 July 2016. Outcomes were efficacy, accuracy, safety, workload and costs. Our search retrieved 356 articles,...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Point accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study

INTRODUCTION There is a need for continuous glucose monitoring in critically ill patients. The objective of this trial was to determine the point accuracy and reliability of a device designed for continuous monitoring of interstitial glucose levels in intensive care unit patients. METHODS We evaluated point accuracy by comparing device readings with glucose measurements in arterial blood by u...

متن کامل

Continuous glucose control in the ICU: report of a 2013 round table meeting

Achieving adequate glucose control in critically ill patients is a complex but important part of optimal patient management. Until relatively recently, intermittent measurements of blood glucose have been the only means of monitoring blood glucose levels. With growing interest in the possible beneficial effects of continuous over intermittent monitoring and the development of several continuous...

متن کامل

Validation of mid-infrared spectroscopy for continuous glucose monitoring: the manage II study

Introduction Intravascular continuous glucose monitoring (CGM) in critically ill patients represents a major advance to improve the quality of care and to decrease the nursing workload dedicated to glycemic control. However, the presence of several physical or chemical interferences can limit the accuracy of the blood glucose readings (BG) measured by the CGM, implying the need for a thorough v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014