Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.
نویسندگان
چکیده
Bone mineral density (BMD) measurements are critical in many research studies investigating skeletal integrity. For pre-clinical research, micro-computed tomography (microCT) has become an essential tool in these studies. However, the ability to measure the BMD directly from microCT images can be biased by artifacts, such as beam hardening, in the image. This three-part study was designed to understand how the image acquisition process can affect the resulting BMD measurements and to verify that the BMD measurements are accurate. In the first part of this study, the effect of beam hardening-induced cupping artifacts on BMD measurements was examined. In the second part of this study, the number of bones in the X-ray path and the sampling process during scanning was examined. In the third part of this study, microCT-based BMD measurements were compared with ash weights to verify the accuracy of the measurements. The results indicate that beam hardening artifacts of up to 32.6% can occur in sample sizes of interest in studies investigating mineralized tissue and affect mineral density measurements. Beam filtration can be used to minimize these artifacts. The results also indicate that, for murine femora, the scan setup can impact densitometry measurements for both cortical and trabecular bone and morphologic measurements of trabecular bone. Last, when a scan setup that minimized all of these artifacts was used, the microCT-based measurements correlated well with ash weight measurements (R(2)=0.983 when air was excluded), indicating that microCT can be an accurate tool for murine bone densitometry.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملBeam Hardening Artifacts: Comparison between Two Cone Beam Computed Tomography Scanners
BACKGROUND AND AIMS At present, cone beam computed tomography (CBCT) has become a substitute for computed tomography (CT) in dental procedures. The metallic materials used in dentistry can produce artifacts due to the beam hard-ening phenomenon. These artifacts decrease the quality of images. In the present study, the number of artifacts as a result of beam hardening in the images of dental imp...
متن کاملMulti-Material Beam Hardening Correction(MMBHC) in Computed Tomography
In computed tomography (CT), the nonlinear attenuation characteristics of polychromatic X-rays cause beam hardening artifacts in the reconstructed images. State-of-theart methods to correct the beam hardening effect are mostly single material precorrections (e.g. water-precorrection), which are far less efficient when more than one material is present in the field of measurement. The use of tho...
متن کاملBeam hardening correction and its influence on the measurement accuracy and repeatability for CT dimensional metrology applications
The beam hardening effect is one of the major artifacts of X-ray computed tomography. It not only complicates medical inspection and material analysis, but also influences the accuracy and repeatability of dimensional measurements. Therefore, many efforts have been devoted to develop beam hardening correction methods since the early 1970s. In practice, the combination of hardware filters (pre-f...
متن کاملCan Dental Cone Beam Computed Tomography Assess Bone Mineral Density?
Mineral density distribution of bone tissue is altered by active bone modeling and remodeling due to bone complications including bone disease and implantation surgery. Clinical cone beam computed tomography (CBCT) has been examined whether it can assess oral bone mineral density (BMD) in patient. It has been indicated that CBCT has disadvantages of higher noise and lower contrast than conventi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bone
دوره 45 6 شماره
صفحات -
تاریخ انتشار 2009