Comparison of MR lymphangiography with a G6 macromolecular contrast agent obtained at 1.5T and 3.0T Systems

نویسندگان

  • Y. Hama
  • M. Bernardo
  • Y. Koyama
  • C. A. Regino
  • M. W. Brechbiel
  • P. L. Choyke
  • H. Kobayashi
چکیده

Y. Hama, M. Bernardo, Y. Koyama, C. A. Regino, M. W. Brechbiel, P. L. Choyke, H. Kobayashi Molecular Imaging Program, NCI/NIH, Bethesda, Maryland, United States, Molecular Imaging Program, SAIC-Frederick, NCI/NIH, Bethesda, Maryland, United States, Radiation Oncology Branch, NCI/NIH, Bethesda, Maryland, United States Introduction Higher field strength magnets are theoretically superior in signal to noise, which translates into better spatial and temporal resolution. Fortunately, small molecular weight imaging agents such as Gd-DTPA show little change in relaxivity between the field strengths of 1.5T and 3.0T. However, most of the macro-molecular contrast agents show more significantly decreased R1 and increased R2 relaxivities when the magnetic field changes from 1.5T to 3T. Since T2 and T2* effects should be enhanced on 3T system compared with those at 1.5T, T1 contrast induced by macromolecular contrast agents can be compromised at 3T as compared with 1.5T. Practical disadvantages caused by these effects have not been reported on a 3T system compared with 1.5T. In this study, MR lymphangiograpy (MRL) in mice with a G6 dendrimer-based macro-molecular contrast agent (~10nm in diameter; 204 Gd ions on a molecule) was compared at 1.5T and 3.0T. Images obtained using both T1-weighted 3D-fast spoiled gradient echo (3D-fSPGR) and T2/T1-weighted 3D-fast imaging employing steady-state acquisition (3D-FIESTA-C) with identical imaging parameters at both field strengths in order to evaluate the effect of high magnetic field on the detectability of macromolecular contrast agents. Methods Contrast agent: A polyamidoamine-G6 dendrimer (58 kD) based nano-size MRI contrast agent coupled with 2-(p-isothiocyanatobenzyl)-6-methyldiethylenetriamine-pentaacetic acid (1B4M) and 204 Gd(III) ions (G6; 220 kD; ~10 nm in diameter) was synthesized to perform MRL. Relaxivity: To validate R1 and R2 relaxivities of G6 agent, we made a phantom, which consists of 0, 0.25, 0.5, 0.75, and 1 mM G6 in PBS together with 0.18 and 0.94 mM Gd-DTPA as internal controls. The phantom was examined with 2Dand 3D-fSPGR using flip angles 0-50° with 5° increments and R1 relaxivity was calculated. Then phantom was examined with multi-echo spin echo (TE; 15, 30, 45, and 60 msec) and R2 relaxivity was calculated on both systems. Animal MRI models: Three groups of 10 week-old normal athymic mice (n=4) were used for; 1. A side-by-side comparison study between 3T and 1.5T system (both GE Signa systems LX at 1.5T and Excite at 3.0T) of the same mouse, 2. Dynamic scans for further optimization of timing and parameters on each system. All mice were anesthetized and injected intracutaneously with 0.005 μmolGd of G6 into the middle phalanges in both upper extremities. All MR images were obtained with a modified Alderman-Grant resonator mouse coil fixed by an in-house constructed coil holder. For the comparative study, a T1-weighted 3D-FIESTA-C [TR/TE 10.8/2.2; bandwidth 41.7 kHz, flip angle 45°, frequency/phase: 384/256, slice thickness 0.6 mm, 2 NEX; scan time 3’42”] and a T2/T1-weighted 3D-fSPGR [TR/TE 14.3/7.0; bandwidth 31.2 kHz, flip angle 30°, frequency/phase: 512/256, slice thickness 0.6 mm, 4 NEX; scan time 4’38”] were used for obtaining coronal images of the contrastenhanced MRL studies. A side-by-side comparison study was performed at 30 min post-injection of contrast agent. In addition, dynamic scans were obtained at 10, 20, and 30 min post-injection of the contrast agents to test shorter TE scans (TR/TE; 9.3/2.3) for 3D-fSPGR and larger flip angles (60°, 70°, 80°) for 3D-FIESTA-C were tested on both systems. Results The R1 and R2 relaxivity of the G6 contrast agent were 33 and 78 /sec/mM at 1.5T and 24 and 82 /sec/mM at 3T, respectively. The 1.5T system showed high axillary LN-to-fat ratios with both 3D-fSPGR (4.5±0.9 vs 3.5±0.9; 1.5T vs 3T, n=8) and 3D-FIESTA-C (2.7±0.2 vs 1.2±0.1; 1.5T vs 3T, n=8, p<0.001). Maximum intensity projections (MIP) obtained with 3D-fSPGR provided good enough contrast for both 1.5T and 3T systems (Fig. 1a, 2a). However, inadequate contrast between the enhanced LN and the surrounding fat tissue obtained with 3D-FIESTA-C on the 3T system compromised the visualization of the lymphatic system (Fig. 1b, 2b). Shorter TE scans with 3D-fSPGR helped to improve the LN-to-fat contrast especially on the 3T system. In contrast, changes of the flip angle with 3D-FIESTA-C did not improve the LN-to-fat contrast on the 3T system. Conclusion When comparing performance of the macromolecular G6 agent at 1.5T and 3.0T, the fat/opacified lymph node ratio was compromised with both 3D-fastSPGR and 3D-FIESTA-C at 3T compared with the 1.5T system probably because of decreased R1 relaxivity of G6 agent and possible T2 and T2* effects. The lymphatic system was almost invisible on 3D-MIP MRL images taken with 3D-FIESTA-C on the 3T system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lymphatic drainage imaging of breast cancer in mice by micro-magnetic resonance lymphangiography using a nano-size paramagnetic contrast agent.

BACKGROUND The presence of lymph node metastases is an important factor in breast cancer patient prognosis. Therefore, the precise identification of sentinel lymph nodes in these patients is critical. Improving current magnetic resonance (MR) imaging methods using a newly synthesized nano-size paramagnetic molecule, G6, as a contrast agent, provides an attractive means toward attaining this goa...

متن کامل

Non-Contrast-Enhanced Pulmonary MR imaging: Comparison of Capability for Nodule Screening between 1.5T and 3.0T MR Systems

INTRODUCTION: Detection of pulmonary nodule, lung cancer screening and metastases surveillance are widely performed by chest radiograph and/ or multidetector-row CT (MDCT) in routine clinical practice. Although higher detection rate and diagnostic capability of MDCT are considered as the major advantage, higher radiation exposure than chest radiograph is also considered as the fundamental probl...

متن کامل

MR imaging of the fetal brain at 1.5T and 3.0T field strengths: comparing specific absorption rate (SAR) and image quality.

OBJECTIVES Our two objectives were to evaluate the feasibility of fetal brain magnetic resonance imaging (MRI) using a fast spin echo sequence at 3.0T field strength with low radio frequency (rf) energy deposition (as measured by specific absorption rate: SAR) and to compare image quality, tissue contrast and conspicuity between 1.5T and 3.0T MRI. METHODS T2 weighted images of the fetal brain...

متن کامل

CEMRA in neonatal and pediatric congenital vascular diseases at 1.5T and 3.0T: comparison of an intravascular contrast agent (Gadofosveset) with an extracellular agent (Gadopentetate Dimeglumine)

Methods Twenty-eight pediatric patients with CCHD underwent CEMRA at 3.0T (n=16) or at 1.5T (n=12). Sixteen patients were imaged with gadofosveset; 9 at 3.0T (age 1.00 ± 1.58 months; weight 2.38 ± 1.13 kg) and 7 at 1.5T (age 8.00 ± 7.83 months; weight 5.06 ± 3.09 kg). Twelve patients were imaged with gadopentetate; 7 at 3.0T (age 1.00 ± 1.41 months; weight 3.02 ± 1.59 kg) and 5 at 1.5T (age 6.6...

متن کامل

Influence of the Magnetic Field Strength on Image Contrast in Gd-EOB-DTPA-enhanced MR Imaging: Comparison between 1.5T and 3.0T

PURPOSE We quantitatively investigated hepatic enhancement in gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) imaging at 1.5T and 3.0T. METHODS A total of 40 patients who underwent Gd-EOB-DTPA-enhanced MR imaging were included in the study. Precontrast and hepatobiliary-phase images acquired at a low flip angle (FA, 12°) and hepatobil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005