MicroRNA in vitro diagnostics using immunoassay analyzers.

نویسندگان

  • Andreas Kappel
  • Christina Backes
  • Yiwei Huang
  • Sachli Zafari
  • Petra Leidinger
  • Benjamin Meder
  • Herbert Schwarz
  • Walter Gumbrecht
  • Eckart Meese
  • Cord F Staehler
  • Andreas Keller
چکیده

BACKGROUND The implementation of new biomarkers into clinical practice is one of the most important areas in medical research. Besides their clinical impact, novel in vitro diagnostic markers promise to have a substantial effect on healthcare costs. Although numerous publications report the discovery of biomarkers, only a fraction of those markers are routinely used. One key challenge is a measurement system that is compatible with clinical workflows. METHODS We designed a new immunoassay for microRNA (miRNA) quantification. The assay combines streptavidin-linked microparticles, a biotinylated catcher oligonucleotide complementary to a single miRNA species, and finally, a monoclonal antibody to DNA/RNA heterohybrids labeled with acridinium ester. Importantly, our assay runs on standard immunoassay analyzers. After a technical validation of the assay, we evaluated the clinical performance on 4 Alzheimer disease miRNAs. RESULTS Our assay has an analytical specificity of 99.4% and is at the same time sensitive (concentrations in the range of 1 pmol/L miRNA can be reliably profiled). Because the novel approach did not require amplification steps, we obtained high reproducibility for up to 40 biological replicates. Importantly, our assay prototype exhibited a time to result of <3 h. With human blood samples, the assay was able to measure 4 miRNAs that can detect Alzheimer disease with a diagnostic accuracy of 82% and showed a Pearson correlation >0.994 with the gold standard qRT-PCR. CONCLUSIONS Our miRNA immunoassay allowed the measurement of miRNA signatures with sufficient analytical sensitivity and high specificity on commonly available laboratory equipment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First-trimester Combined Screening for Trisomies 21, 18, and 13 by Three Closed Chemiluminescence Immunoassay Analyzers (an Experiment on Iranian Pregnant Women)

Background: Pregnancy-associated plasma protein-A (PAPP-A) and free β-human chorionic gonadotropin (free β-hCG) as valuable biochemical biomarkers are used to screen down syndrome, Edwards syndrome, and Patau syndrome in the first trimester of pregnancy. Closed immunoassay analyzers are regarded as sophisticated platforms to measure biochemical biomarkers. This study compared the performance of...

متن کامل

340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, ...

متن کامل

Serum total prolactin and monomeric prolactin reference intervals determined by precipitation with polyethylene glycol: evaluation and validation on common immunoassay platforms.

BACKGROUND Macroprolactin is an important source of immunoassay interference that commonly leads to misdiagnosis and mismanagement of hyperprolactinemic patients. We used the predominant immunoassay platforms for prolactin to assay serum samples treated with polyethylene glycol (PEG) and establish and validate reference intervals for total and monomeric prolactin. METHODS We used the Architec...

متن کامل

First 25-hydroxyvitamin D assay for general chemistry analyzers.

25-Hydroxyvitamin D [25(OH)D], the predominant circulating form of vitamin D, is an accurate indicator of the general vitamin D status of an individual. Because vitamin D deficiencies have been linked to several pathologies (including osteoporosis and rickets), accurate monitoring of 25(OH)D levels is becoming increasingly important in clinical settings. Current 25(OH)D assays are either chroma...

متن کامل

Methodology and subspecialty consolidation in the clinical laboratory.

The design of instruments as automated workstations for the clinical laboratory has evolved steadily over the last two decades. The grouping of assays into clinical chemistry disciplines has been largely influenced by the instrumentation available, e.g., multicomponent chemistry analyzers and specialty analyzers, including analyte-specific analyzers, blood gas analyzers, nephelometers, instrume...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 61 4  شماره 

صفحات  -

تاریخ انتشار 2015