Tandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer

نویسندگان

  • Obed Rachel Ibhade
  • Oyekunle Emmanuel Oyeyemi
  • Akinlade Bidemi Idayat
  • Ntekim Atara I.
چکیده

PURPOSE In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ring dwell time ratio used at the first HDR BT center in Nigeria, and compare it with an alternative source loading pattern. MATERIAL AND METHODS At the Radiotherapy Department, University College Hospital (UCH), Ibadan, Nigeria, a total of 370 standard treatment plans in two alternative sets were generated with HDR basic 2.6 software for one hundred and eighty five cervical cancer patients. The initial 185 individual plans were created for clinical treatment using the tandem-ring dwell time ratio of 1 : 1. Modifying the initial applicator loading ratio, the second set of plans with related dose data were also obtained for study purposes only. Total reference air kerma (TRAK), total time index (TTI), ICRU volume, treatment time, point B dose, ICRU bladder dose, and rectal points dose were evaluated for both sets of plans. RESULTS The means of all evaluated dose parameters decreased when the existing tandem-ring dwell time ratio (1 : 1) was modified to other dwell weightings (1 : 1 - 3 : 1). These reductions were 13.43% (ICRU volume), 9.83% (rectal dose), 6.68% (point B dose), 6.08% (treatment time), 5.90% (TRAK), 5.88% (TTI), and 1.08% (bladder dose). Correspondingly, coefficients of variation changed by -7.98%, -5.02%, -5.23%, -4.20%, -3.93%, 8.65%, and 3.96% from the existing pattern to the alternative one. CONCLUSION Tandem-ring dwell time ratio has significant influence on dosimetric parameters. This study has indicated the need to modify the existing planning approach at UCH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer

PURPOSE To evaluate whether Co-60 is equivalent to Ir-192 for HDR cervical brachytherapy, through 3D-DVH dose comparisons in standard and optimised plans. Previous studies have only considered 2D dosimetry, point dose comparisons or identical loading. Typical treatment times and economics are considered. MATERIAL AND METHODS Plans were produced for eight cervix patients using Co-60 and Ir-192...

متن کامل

Independent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader

Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...

متن کامل

Comparison the treatment time of cobalt and iridium sources in HDR brachytherapy

Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...

متن کامل

Evaluating variation of Hot Spot Location in order to radiobiological calculation of Organ at Risk in High-dose- rate Brachytherapy of Cervical Cancer

Introduction: Gynecological malignancies present challenges in determining an appropriate volumetric dose due to the highly variable physiologic activity of the surrounding tissue. Because of the high doses used in brachytherapy, surrounding structures have the potential to move around in the dose region and receive unknown amounts of radiation. Calculating hotspot region from ...

متن کامل

Does help structures play a role in reducing the variation of dwell time in IPSA planning for gynaecological brachytherapy application?

PURPOSE To report our experience of dosimetric comparison of IPSA and manual plans, with a focus on the use of help structures (HS) during optimization. MATERIAL AND METHODS 33 patients who underwent MR image-based HDR intracavitary-brachytherapy for cervix cancer based on GYN-ESTRO recommendations were selected for evaluation. Tandem/ovoid (T/O) and Vienna applicators were used. HS of diamet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015