INTRODUCTION Fatigue resistance of ProFile, Vortex Blue, and TRUShape files in artificial single curvature and in 2 different artificial double curvature canals was evaluated. METHODS Three files (ProFile, Vortex Blue [size 20/.06], and TRUShape [size 20/.06v]) were subjected to fatigue tests in a single curvature (group 1: 60° curvature) and 2 different double curvatures (group 2: 60° and 30° curvatures; group 3: two 60° curvatures). The time to fracture and the total number of cycles to failure were recorded. The fracture surfaces of the fragments were examined with a scanning electron microscope. RESULTS All files had significantly higher fatigue resistance in a single curvature canal than in the double curvature canals. In a single curvature group, the time to fracture of TRUShape and ProFile was longer than in Vortex Blue files. In both double curvature groups, TRUShape had the longest time to fracture among all files. The fatigue resistance (the time to fracture and number of cycles to failure) of ProFile and Vortex Blue was lower in group 3 than in group 2 (P < .05). However, there was no significant difference in fatigue resistance of TRUShape in the double curvature groups. The length of the fragment of TRUShape was longer than in Vortex Blue and ProFile files in group 3 (P < .05). CONCLUSIONS The fatigue performance of TRUShape is different in double curvature canals, compared with conventional nickel-titanium rotary files. The fatigue resistance of TRUShape was superior to ProFile and Vortex Blue in double curvature canals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.

AIM To determine how instrument design affects the fatigue life of two nickel-titanium (Ni-Ti) rotary systems (Mtwo and ProTaper) under cyclic fatigue stress in simulated root canals. METHODOLOGY Cyclic fatigue testing of instruments was performed in stainless steel artificial canals with radii of curvature of 2 or 5 mm and an angle of curvature of 60 degrees . A total of 260 instruments were...

متن کامل

Cyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro sem analysis.

INTRODUCTION Instrument separation is a serious concern in endodontics. Stainless steel instruments usually deform before they separate whereas Nickel Titanium instruments do not show any sign of deformation. AIM of the present study was to compare the cyclic rotations needed to fracture three different rotary nickel titanium endodontic instruments namely Profile, K3 Endo, RaCe in simulated c...

متن کامل

Predicting in vivo failure of rotary nickel-titanium endodontic instruments under cyclic fatigue.

The aim of this study was to examine the lifespan or number of cycles to failure of tapered rotary nickel-titanium (Ni-Ti) endodontic instruments. Simulated root canals with different curvatures were used to determine a relation between canal curvature and instrument lifespan. Using a novel mathematical model for the deformation of pseudoelastic Ni-Ti alloy, it was shown that maximum stress nee...

متن کامل

An in vitro assessment of the physical properties of novel Hyflex nickel-titanium rotary instruments.

AIM To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickel-titanium alloy. METHODOLOGY The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination,...

متن کامل

A dozen ways to prevent nickel-titanium rotary instrument fracture.

BACKGROUND and Overview. With the increased use of nickel-titanium (NiTi) rotary instruments for root canal preparation in endodontics, instrument fracture has become more prevalent. Extensive research has been conducted on the physical properties and mechanical characteristics of NiTi rotary instruments, as well as the factors that can contribute to instrument failure. NiTi rotary instruments ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 42 6  شماره 

صفحات  -

تاریخ انتشار 2016