Pigeon Breeder's Disease: Multi-Detector Row Computed Tomography Imaging.

نویسندگان

  • Mecit Kantarci
  • Berrin Arslan
  • Mehmet Karacan
  • İhsan Yuce
چکیده

Correspondence to: Ihsan Yuce, Solakzade Mah. Alvarli Mehmet Efendi Cad. Ozlider Yapı Kop. B Blok 8/28, Palandoken, Erzurum, Turkey Phone: +90 506 282 49 91 Fax: +90 442 236 13 01 e-mail: [email protected] doi:10.5152/eajm.2011.15 Received: December 06, 2010 / Accepted: December 07, 2010 A 10-year-old boy was referred to our department for computed tomography of the thorax because of chronic cough, fever and progressive dyspnea. His chest X-ray showed bilateral, diffuse reticulonodular shadowing. Computed tomographic scan of the thorax demonstrated bilateral, diffuse and punctuate pulmonary nodules with patchy ground-glass appearances (Figure A). The nodules caused a pulmonary tree in the 3D images. In fact, the pulmonary tree was an air bubble (Figure B). Despite antibiotic therapy, the symptoms persisted. Laboratory examination revealed an ESR rate of 42 mm per hour. Leukocyte count and C-reactive protein levels were both normal. The patient’s previous history revealed that he previously had pigeon breeder’s disease. Pigeon breeder’s disease rarely occurs in childhood. The disease typically appears in the bronchioles and causes alveolar type III type IV allergic reactions [1]. The patient’s history, especially the existence of chronic cough and progressive dyspnea and clinical examination showed wheezing crackles and abnormal laboratory values. Chest X-ray, MDCT findings and lung function tests demonstrated a restrictive defect, and tracing the specific IgG precipitins in the breeder’s serum suggests the diagnosis of pigeon breeder’s disease [2]. MDCT is a reliable tool for diagnosing the presence and severity of pigeon breeder’s disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiplanar and 3D imaging of the central airways: comparison of image quality and radiation dose of single-detector row CT and multi-detector row CT at differing tube currents in dogs.

PURPOSE To compare in an animal model the image quality of multiplanar reformation and three-dimensional (3D) reconstruction images of the central airways by using single-detector row computed tomography (CT) and multi-detector row CT at varied tube currents and to compare radiation dose. MATERIALS AND METHODS Five dogs each underwent five consecutive helical CT examinations (one single-detec...

متن کامل

Using multidetector row computed tomography to diagnose and stage pancreatic carcinoma: the problems and the possibilities.

The sensitivity of computed tomography (CT) in the diagnosis of pancreatic neoplasms and accurate tumor staging has significantly been improved by the use of thin-section multi-detector row CT techniques. Greater table speed, improved tube cooling, high resolution imaging and the possibility of isotropic voxels have led to optimal multiplanar reconstruction in any arbitrary plane and particular...

متن کامل

AAPM / RSNA PHYSICS TUTORIAL 1495 AAPM / RSNA Physics Tuto - rial for Residents Physics of Cardiac Imaging with Multiple - Row Detector CT 1

Cardiac imaging with multiple-row detector computed tomography (CT) has become possible due to rapid advances in CT technologies. Images with high temporal and spatial resolution can be obtained with multiple-row detector CT scanners; however, the radiation dose associated with cardiac imaging is high. Understanding the physics of cardiac imaging with multiple-row detector CT scanners allows op...

متن کامل

Non-invasive imaging of sutureless vein graft anastomosis with 16-slice multi-detector row spiral computed tomography.

Contrast-enhanced 16-slice multi-detector row spiral computed tomography (MDCT) has been shown to be useful for non-invasive visualization of aortocoronary bypass grafts (CABG). This new-generation scanner could be a good alternative to the common invasive coronary angiography. In this article, we report a patient operated on with the St. Jude Medical, Inc, Symmetry Bypass System (Aortic Connec...

متن کامل

Cancerogenesis Risks between 64 and 320 Row Detector CT for Coronary CTA Screening

OBJECTIVES This study compares cancerogenesis risks posed by the 64 row detector and the 320 row detector computed tomography scanners used during coronary computed tomography angiography (CCTA) following decennial screening guidelines. MATERIAL AND METHODS Data of the radiation absorbed after CCTA by lung, thyroid, and female breast in patients between 50 and 70 years of age obtained from pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Eurasian journal of medicine

دوره 43 1  شماره 

صفحات  -

تاریخ انتشار 2011