Construction and economics of a pilot/full-scale biological trickling filter reactor for the removal of volatile organic compounds from polluted air.

نویسندگان

  • M A Deshusses
  • T S Webster
چکیده

The design and the construction of an actual 8.7-m3 pilot/full-scale biotrickling filter for waste air treatment is described and compared with a previous conceptual scale-up of a laboratory reactor. The reactor construction costs are detailed and show that about one-half of the total reactor costs ($97,000 out of $178,000) was for personnel and engineering time, whereas approximately 20% was for monitoring and control equipment. A detailed treatment cost analysis demonstrated that, for an empty bed contact time of 90 sec, the overall treatment costs (including capital charges) were as low as $8.7/1000 m3air in the case where a nonchlorinated volatile organic compound (VOC) was treated, and $14/1000 m3air for chlorinated compounds such as CH2Cl2. Comparison of these costs with conventional air pollution control techniques demonstrates excellent perspectives for more field applications of biotrickling filters. As the specific costs of building and operating biotrickling filter reactors decrease with increasing size of the reactor, the cost benefit of biotrickling filtration is expected to increase for full technical-scale bioreactors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه روش بیولوژیکی و بیوالکتروشیمیایی در تصفیه فاضلابهای حاوی فرمالدوئید

Introduction:Among the pollutants in waste gases, volatile organic carbons (VOCs) are very harmful for human, animals and plants. Formaldehyde is a member of VOCs family and is very toxic, mutagen and carcinogen. For removing formaldehyde, Some biological methods for treating waste gases such as bio-trickling filter reactor (BTFR) have been developed by scientists. The aim of this study was to ...

متن کامل

Comparative Scale-Up and Cost Estimation of a Biological Trickling Filter and a Three-Phase Airlift Bioreactor for the Removal of Methylene Chloride from Polluted Air

Laboratory scale biological trickling filters and three-phase airlift bioreactors have been studied for the elimination of methylene chloride (or dichloromethane) vapors from waste air, and the results used herein for the design of small industrial-scale reactors. The conditions chosen for scale-up were an air flow rate of 100 m3 h-1, a methylene chloride inlet concentration of 2 g m-3, and a t...

متن کامل

Retrofitting existing chemical scrubbers to biotrickling filters for H2S emission control.

Biological treatment is a promising alternative to conventional air-pollution control methods, but thus far biotreatment processes for odor control have always required much larger reactor volumes than chemical scrubbers. We converted an existing full-scale chemical scrubber to a biological trickling filter and showed that effective treatment of hydrogen sulfide (H2S) in the converted scrubber ...

متن کامل

Literature Review of Air Pollution Control Biofilters and Biotrickling Filters for Odor and Volatile Organic Compound Removal

A literature study was conducted to compare the feasibility of biofilters and biotrickling filters for the treatment of complex odorous waste air containing hydrogen sulfide (H2S), organic reduced sulfur compounds, and chlorinated and nonchlorinated volatile organic compounds (VOCs). About 40 pilot-plant studies and full-scale applications at wastewater treatment plants and other facilities wer...

متن کامل

An Environmentally Friendly Method for Controlling Biomass in Biotrickling Filters for Air Pollution Control

Biomass accumulation is a major obstacle for long-term, stable operation of biotrickling filters treating high loadings of volatile organic compounds (VOCs). Clogging reduces pollutant removal and increases the pressure drop in biotrickling filters. Several options exist to remove excess biomass or to slow down the accumulation rate, but so far none has succeeded in combining a high VOC removal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 50 11  شماره 

صفحات  -

تاریخ انتشار 2000