چکیده

The purpose of this study is to determine whether gas chromatography (GC)-atomic emission detection (AED) can be used in a low-resolution mode for rapid, accurate determinations of total sulfur in fuels at trace levels to complement other popular methods of total sulfur analysis. A method for the rapid determination of total sulfur in fuels (called "fast GC-AED") is developed. The method is tested on gasoline, jet fuel, kerosene, and diesel fuel with sulfur concentrations ranging from 125 mg/L down to 2.5 mg/L. Fast GC-AED shows better performance than traditional GC-AED for total sulfur determinations, especially for complex mixtures containing many different sulfur-containing compounds at trace levels. This method also shows that GC-AED can be used for both rapid determinations of total sulfur and traditional determinations of speciated sulfur without requiring equipment changes. Fast GC-AED is competitive with other popular methods for sulfur analysis. The 5-min program that is developed for fast GC-AED is comparable with the time scale of other methods, such as wavelength dispersive X-ray fluorescence and UV-fluorescence (2 to 5 min). Fast GC-AED also compares favorably with UV-fluorescence for trace sulfur determinations, demonstrating accuracy down to 2.5-mg/L sulfur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lu...

متن کامل

Quantification and Characterization of Sulfur in Low-Sulfur Reformulated Gasolines by GC-ICP-MS Application

Reducing total sulfur in motor fuels has become a critical air pollution control goal worldwide. As countries mandate ever lower permissible levels of total sulfur in fuels, the environmental monitoring and fuel manufacturing industries have been forced to find more sensitive techniques for analysis. Gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS) has the ...

متن کامل

A Comparison of Sulfur Selective Detectors for Low Level Analysis in Gaseous Streams Application

A comparison of four selective detectors for analysis of single-digit ppb level sulfur is described. A dynamic blending system is used for point of use preparation of low level gaseous mixtures of eight sulfur compounds including H 2 S, COS, CS 2 and selected mercaptans in helium, ethylene, propylene, and carbon dioxide. The criteria to consider for selecting the best detector for an applicatio...

متن کامل

Determination of mustard gas hydrolysis products thiodiglycol and thiodiglycol sulfoxide by gas chromatography-tandem mass spectrometry after trifluoroacetylation.

A method for detecting mustard gas degradation products thiodiglycol (TDG) and thiodiglycol sulfoxide (TDGO) in water and sediment samples using gas chromatography-tandem mass spectrometry (GC-MS/MS) after derivatization with 1-(trifluoroacetyl)imidazole (TFAI) was described. Selected reaction monitoring mode (SRM) of tandem mass spectrometry was developed for analysis of TDG and TDGO derivativ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 2002