New FIGO and Swedish intrapartum cardiotocography classification systems incorporated in the fetal ECG ST analysis (STAN) interpretation algorithm: agreements and discrepancies in cardiotocography classification and evaluation of significant ST events.

نویسندگان

  • Per Olofsson
  • Håkan Norén
  • Ann Carlsson
چکیده

INTRODUCTION The updated intrapartum cardiotocography (CTG) classification system by FIGO in 2015 (FIGO2015) and the FIGO2015-approached classification by the Swedish Society of Obstetricians and Gynecologist in 2017 (SSOG2017) are not harmonized with the fetal ECG ST analysis (STAN) algorithm from 2007 (STAN2007). The study aimed to reveal homogeneity and agreement between the systems in classifying CTG and ST events, and relate them to maternal and perinatal outcomes. MATERIAL AND METHODS Among CTG traces with ST events, 100 traces originally classified as normal, 100 as suspicious and 100 as pathological were randomly selected from a STAN database and classified by two experts in consensus. Homogeneity and agreement statistics between the CTG classifications were performed. Maternal and perinatal outcomes were evaluated in cases with clinically hidden ST data (n = 151). A two-tailed p < 0.05 was regarded as significant. RESULTS For CTG classes, the heterogeneity was significant between the old and new systems, and agreements were moderate to strong (proportion of agreement, kappa index 0.70-0.86). Between the new classifications, heterogeneity was significant and agreements strong (0.90, 0.92). For significant ST events, heterogeneities were significant and agreements moderate to almost perfect (STAN2007 vs. FIGO2015 0.86, 0.72; STAN2007 vs. SSOG2017 0.92, 0.84; FIGO2015 vs. SSOG2017 0.94, 0.87). Significant ST events occurred more often combined with STAN2007 than with FIGO2015 classification, but not with SSOG2017; correct identification of adverse outcomes was not significantly different between the systems. CONCLUSION There are discrepancies in the classification of CTG patterns and significant ST events between the old and new systems. The clinical relevance of the findings remains to be shown.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fetal electrocardiogram: ST waveform analysis in intrapartum surveillance

ST waveform analysis of fetal electrocardiogram (ECG) for intrapartum surveillance (STAN) is a newly introduced method for fetal surveillance. The purpose of this commentary is to assist in the proper use of fetal ECG in combination with cardiotocography (CTG) during labour. Guidelines and recommendations concerning CTG and ST waveform interpretation and classification are stated that were agre...

متن کامل

Limitations of ST analysis in clinical practice: three cases of intrapartum metabolic acidosis.

OBJECTIVE To examine detailed intrapartum events in cases of neonatal metabolic acidosis despite monitoring using STAN (cardiotocography [CTG] plus ST waveform analysis of fetal electrocardiogram [ECG]). DESIGN Retrospective case review. SETTING High-risk pregnancies monitored by STAN. METHODS Case note review was performed in newborns with metabolic acidosis where no significant ST chang...

متن کامل

Biphasic ST should not be omitted from STAN clinical guidelines.

Sir, We read with interest the study of Becker et al. on the added predictive value of biphasic events in ST analysis (STAN) (1). The authors used the cardiotocography (CTG) arm of the Swedish randomized controlled trial where STAN was recorded, but blinded for the clinician. Cases with Biphasic ST and concomitant CTG abnormalities indicating intervention were compared with all remaining cases ...

متن کامل

Effect of availability of fetal ECG monitoring on operative deliveries.

OBJECTIVE The objective of our study was to test the hypothesis that the availability and selective use of STAN in conjunction with cardiotocography for intrapartum monitoring, lowers the incidence of operative deliveries for fetal distress. DESIGN Observational study. SETTING Delivery suite of the National University Hospital, Singapore. METHODS The data regarding intrapartum cesarean se...

متن کامل

Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial.

BACKGROUND Previous studies indicate that analysis of the ST waveform of the fetal electrocardiogram provides information on the fetal response to hypoxia. We did a multicentre randomised controlled trial to test the hypothesis that intrapartum monitoring with cardiotocography combined with automatic ST-waveform analysis results in an improved perinatal outcome compared with cardiotocography al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta obstetricia et gynecologica Scandinavica

دوره 97 2  شماره 

صفحات  -

تاریخ انتشار 2018