Effectiveness of sequential automatic-manual home respiratory polygraphy scoring.

نویسندگان

  • Juan F Masa
  • Jaime Corral
  • Ricardo Pereira
  • Joaquin Duran-Cantolla
  • Marta Cabello
  • Luis Hernández-Blasco
  • Carmen Monasterio
  • Alberto Alonso-Fernandez
  • Eusebi Chiner
  • Francisco-José Vázquez-Polo
  • Jose M Montserrat
چکیده

Automatic home respiratory polygraphy (HRP) scoring functions can potentially confirm the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS) (obviating technician scoring) in a substantial number of patients. The result would have important management and cost implications. The aim of this study was to determine the diagnostic cost-effectiveness of a sequential HRP scoring protocol (automatic and then manual for residual cases) compared with manual HRP scoring, and with in-hospital polysomnography. We included suspected SAHS patients in a multicentre study and assigned them to home and hospital protocols at random. We constructed receiver operating characteristic (ROC) curves for manual and automatic scoring. Diagnostic agreement for several cut-off points was explored and costs for two equally effective alternatives were calculated. Of 366 randomised patients, 348 completed the protocol. Manual scoring produced better ROC curves than automatic scoring. There was no sensitive automatic or subsequent manual HRP apnoea-hypopnoea index (AHI) cut-off point. The specific cut-off points for automatic and subsequent manual HRP scorings (AHI >25 and >20, respectively) had a specificity of 93% for automatic and 94% for manual scorings. The costs of manual protocol were 9% higher than sequential HRP protocol; these were 69% and 64%, respectively, of the cost of the polysomnography. A sequential HRP scoring protocol is a cost-effective alternative to polysomnography, although with limited cost savings compared to HRP manual scoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study between Sequential Automatic and Manual Home Respiratory Polygraphy Scoring Using a Three-Channel Device: Impact of the Manual Editing of Events to Identify Severe Obstructive Sleep Apnea

Objective. According to current guidelines, autoscoring of respiratory events in respiratory polygraphy requires manual scoring. The aim of this study was to evaluate the agreement between automatic analysis and manual scoring to identify patients with suspected OSA. Methods. This retrospective study analyzed 791 records from respiratory polygraphy (RP) performed at home. The association grade ...

متن کامل

Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea.

This study assessed the accuracy of a cardiorespiratory monitoring device versus polysomnography for the diagnosis of suspected sleep apnoea/hypoponea syndrome (SAS). A total of 86 patients (89% male, mean age 52 yrs) that had been referred to a sleep laboratory with a clinical diagnosis of SAS underwent cardiorespiratory polygraphy in an unattended mode using an ambulatory device (MERLIN). Ana...

متن کامل

Effectiveness of home respiratory polygraphy for the diagnosis of sleep apnoea and hypopnoea syndrome.

INTRODUCTION Home respiratory polygraphy (HRP) may be a cost-effective alternative to polysomnography for the diagnosis of sleep apnoea-hypopnoea syndrome (SAHS), but stronger evidence is needed. Normally, patients transport HRP equipment from the hospital to home and back, which may create difficulties for some patients. OBJECTIVES To determine both the diagnostic efficacy and cost of HRP (w...

متن کامل

[Validation of a respiratory polygraphy system in the diagnosis of sleep apnea syndrome].

OBJECTIVE To validate a cardiorespiratory polygraphy system (BITMED NGP 140) by comparing it to conventional polysomnography in the diagnosis of sleep apnea-hypopnea syndrome. PATIENTS AND METHODS Polysomnography and cardio-respiratory polygraphy were performed simultaneously on 103 consecutive patients referred because of suspected sleep apnea-hypopnea syndrome. The Bland and Altman method a...

متن کامل

Conventional Polysomnography Is Not Necessary for the Management of Most Patients with Suspected Obstructive Sleep Apnea. Noninferiority, Randomized Controlled Trial.

RATIONALE Home respiratory polygraphy may be a simpler alternative to in-laboratory polysomnography for the management of more symptomatic patients with obstructive sleep apnea, but its effectiveness has not been evaluated across a broad clinical spectrum. OBJECTIVES To compare the long-term effectiveness (6 mo) of home respiratory polygraphy and polysomnography management protocols in patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2013