Fluoride release from restorative materials.
نویسندگان
چکیده
The aim of this study was to evaluate in vitro fluoride (F) release from 4 restorative materials (3M ESPE): Ketak Molar Easymix [KME - conventional glass ionomer cement (GIC)]; Rely-X luting 2 [RL2 - resin-modified GIC (RMGIC)]; Vitremer (VIT- RMGIC); and Filtek Z250 [Z250 - negative control]. Disc-shaped specimens were fabricated according to the manufacturer's instructions and placed into 10 mL of reverse osmosis water at 37°C until the analyses were done using a liquid membrane for selective F ion electrode (Orion 710). F release was evaluated every 6 h in the first day and thereafter daily during 28 days (d). The results were analyzed statistically by two-way ANOVA and Tukey's test (α=0.05). Mean F release and standard deviation values (in ppm) were: KME: 6 h- 0.34 ± 0.04; 24 h- 1.22 ± 0.30; 7 d- 0.29 ± 0.09; 14 d- 0.20 ± 0.04; 28 d- 0.16 ± 0.01; RL2: 6 h- 2.46 ± 0.48; 24 h-12.33 ± 2.93; 7 d- 1.37 ± 0.38; 14 d- 0.80 ± 0.13; 28 d- 0.80 ± 0.21; VIT: 6 h- 0.98 ± 0.35; 24 h- 4.35 ± 1.22; 7 d- 0.66 ± 0.23; 14 d- 0.40 ± 0.07; 28 d- 0.39 ± 0.08; Z250: 6 h- 0.029 ± 0.001; 24 h- 0.024 ± 0.009; 7 d- 0.023 ± 0.004; 14 d- 0.025 ± 0.001; 28 d- 0.028 ± 0.001. RL2 RMGIC released more F than the other materials in all periods. The greatest release of F occurred in the first 24 h.
منابع مشابه
The Comparison of Solubility and Release of Fluoride from Easthetic Restorative Materials in Water and Acid: An In Vitro Study
Background & Aims: Secondary caries is one of the most common problems in restorative dentistry. The release of flouride ions could substantially benefit the tooth enamel and neigboring dentin because flourid can combat caries. The purpose of this in vitro study was to evaluate the solubility rate and release of fluoride from tooth-colored restorative materials (Iono CID, Fuji II LC, FugiIX, Fu...
متن کاملAn estimation of fluoride release from various dental restorative materials at different pH: In vitro study.
BACKGROUND In the mid of 1980s, the cariostatic effect of fluoride ions on enamel caries had been demonstrated in many studies. The use of fluoride releasing dental restorative materials has seen increasing from many years for the specific purpose of leaching of fluoride into the surrounding tissues to inhibit secondary dental caries as well as prevention of caries in the newly erupted tooth. I...
متن کاملFlouride release from various restorative materials.
Fluoride release from six light-activated restorative materials, including two resinmodified glass-ionomers, two composites, and two compomers, was evaluated and compared with one conventional acid-based glass-ionomer cement. The amount and rate of release varied among the tested materials. Both resin-modified glass-ionomers and the conventional acid-base glass-ionomer cements released more flu...
متن کاملFluoride and aluminum release from restorative materials using ion chromatography
OBJECTIVE The aim of this study was to determine the amounts of fluoride and aluminum released from different restorative materials stored in artificial saliva and double-distilled water. MATERIAL AND METHODS Cylindrical specimens (10 x 1 mm) were prepared from 4 different restorative materials (Kavitan Plus, Vitremer, Dyract Extra, and Surefil). For each material, 20 specimens were prepared,...
متن کاملZinc Interaction with Glass-Ionomer Restorative Materials
The purpose of this study was to evaluate the effect of addition of zinc sulfate to conventional and resinmodified glass ionomer restorative materials. The samples were prepared by addition of zinc sulfate to glass ionomer at different concentrations. The samples were tested for fluoride, zinc and aluminum release at different time intervals. The antibacterial activity of the restorative materi...
متن کاملMicrohardness and fluoride release of restorative materials in different storage media.
This study evaluated the surface microhardness and fluoride release of 5 restorative materials - Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil - in two storage media: distilled/deionized water and a pH-cycling (pH 4.6). Twelve specimens of each material, were fabricated and the initial surface microhardness (ISM) was determined in a Shimadzu HMV-2000 microhardness tester (static l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 22 5 شماره
صفحات -
تاریخ انتشار 2011