Leukocyte esterase strip test: matched for musculoskeletal infection society criteria.
نویسندگان
چکیده
BACKGROUND The presence of leukocyte esterase in the synovial fluid has recently been proposed as a marker for periprosthetic joint infection. However, the sensitivity and specificity of leukocyte esterase has not been determined when matched for the current, most inclusive Musculoskeletal Infection Society (MSIS) criteria for periprosthetic joint infection. METHODS The presence of leukocyte esterase was prospectively evaluated in synovial joint aspirates from hips and knees from May 2009 to May 2013. The cohort consisted of 189 hip and knee aspirations (fifty-two positive and 137 negative for infection). If the aspirate was bloody, a centrifuge was used to precipitate red blood cells and obtain clear synovial fluid. A standard chemical test strip (graded as negative, trace, +, or ++) was used to detect the presence of leukocyte esterase. The sensitivity, specificity, positive predictive value, and negative predictive value of the leukocyte esterase strip test were calculated using ++ and ++/+ as two positive strip result scenarios. RESULTS Synovial fluid was obtained from 221 joints that underwent revision total hip or total knee arthroplasty for either mechanical failure or periprosthetic infection. Due to the lack of adequate criteria for MSIS criteria classification, thirty-two joints were excluded. The leukocyte esterase test with a threshold of +/++ had a sensitivity, specificity, positive predictive value, and negative predictive value of 79.2% (95% confidence interval [CI], 65.9% to 89.2%), 80.8% (95% CI, 73.3% to 87.1%), 61.8% (95% CI, 49.2% to 73.3%), and 90.1% (95% CI, 84.3% to 95.4%), respectively. Using the ++ as a positive leukocyte esterase result, the sensitivity, specificity, positive predictive value, and negative predictive value were 66.0% (95% CI, 51.7% to 78.5%), 97.1% (95% CI, 92.6% to 99.2%), 89.7% (95% CI, 75.8% to 97.1%), and 88.0% (95% CI, 81.7% to 92.7%), respectively. CONCLUSIONS When matched to the current MSIS criteria, the leukocyte esterase strip test yielded a high specificity, positive predictive value, negative predictive value, and moderate sensitivity. These results demonstrate that leukocyte esterase is an accurate, effective marker of periprosthetic joint infection as defined by the MSIS criteria. The leukocyte esterase strip test is a valuable tool that can be used in conjunction with the current battery of diagnostic tests available.
منابع مشابه
The Alpha-defensin Test for Periprosthetic Joint Infection Outperforms the Leukocyte Esterase Test Strip
BACKGROUND Synovial fluid biomarkers have demonstrated diagnostic accuracy surpassing the currently used diagnostic tests for periprosthetic joint infection (PJI). QUESTIONS/PURPOSES The purpose of this study is to directly compare the sensitivity and specificity of the synovial fluid α-defensin immunoassay to the leukocyte esterase (LE) colorimetric test strip. METHODS Synovial fluid was c...
متن کاملComparison of Leukocyte Esterase Testing of Synovial Fluid with Synovial Histology for the Diagnosis of Periprosthetic Joint Infection
BACKGROUND Periprosthetic joint infection (PJI) is a complication of total joint arthroplasty (TJA). The leukocyte esterase (LE) strip test and histology are diagnostic methods for PJI. The aims of this study were to determine the sensitivity and specificity of the LE strip test and to compare it with histology in the diagnosis of PJI. MATERIAL AND METHODS Between January and December 2015, 93 ...
متن کاملDiagnosis of periprosthetic joint infection: the utility of a simple yet unappreciated enzyme.
BACKGROUND The white blood-cell count and neutrophil differential of the synovial fluid have been reported to have high sensitivity and specificity in the diagnosis of periprosthetic infection following total knee arthroplasty. We hypothesized that neutrophils recruited into an infected joint secrete enzymes that may be used as markers for infection. In this prospective study, we determined the...
متن کاملLeukocyte Esterase as a Biomarker in the Diagnosis of Periprosthetic Joint Infection
BACKGROUND Total joint arthroplasty (TJA) has been one of the most rewarding interventions for treating patients suffering from joint disorders. However, periprosthetic joint infection (PJI) is a serious complication that frequently accompanies TJA. Our study aimed to investigate the application of the leukocyte esterase (LE) strip in the diagnosis of PJI. MATERIAL AND METHODS From October 2014...
متن کاملUsefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis
OBJECTIVE A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. HYPOTHESIS The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 96 22 شماره
صفحات -
تاریخ انتشار 2014