Choice of operating voltage for a transmission electron microscope.
نویسنده
چکیده
An accelerating voltage of 100-300kV remains a good choice for the majority of TEM or STEM specimens, avoiding the expense of high-voltage microscopy but providing the possibility of atomic resolution even in the absence of lens-aberration correction. For specimens thicker than a few tens of nm, the image intensity and scattering contrast are likely to be higher than at lower voltage, as is the visibility of ionization edges below 1000eV (as required for EELS elemental analysis). In thick (>100nm) specimens, higher voltage ensures less beam broadening and better spatial resolution for STEM imaging and EDX spectroscopy. Low-voltage (e.g. 30kV) TEM or STEM is attractive for a very thin (e.g. 10nm) specimen, as it provides higher scattering contrast and fewer problems for valence-excitation EELS. Specimens that are immune to radiolysis suffer knock-on damage at high current densities, and this form of radiation damage can be reduced or avoided by choosing a low accelerating voltage. Low-voltage STEM with an aberration-corrected objective lens (together with a high-angle dark-field detector and/or EELS) offers atomic resolution and elemental identification from very thin specimens. Conventional TEM can provide atomic resolution in low-voltage phase-contrast images but requires correction of chromatic aberration and preferably an electron-beam monochromator. Many non-conducting (e.g. organic) specimens damage easily by radiolysis and radiation damage then determines the TEM image resolution. For bright-field scattering contrast, low kV can provide slightly better dose-limited resolution if the specimen is very thin (a few nm) but considerably better resolution is possible from a thicker specimen, for which higher kV is required. Use of a phase plate in a conventional TEM offers the most dose-efficient way of achieving atomic resolution from beam-sensitive specimens.
منابع مشابه
High quality YBa2Cu307 Josephson junctions made by direct electron beam writing
High-T, Josephson junctions have been fabricated by direct electron beam writing over YBa,C&O, thin-tilm microbridges, using scanning transmission electron microscope (STEM) with an accelerating voltage of W-120 kV. Annealing at 330-380 K increases T, and I, of the junctions and makes them more stable. In the operating range of a few degrees below T,, the junctions show 100% magnetic field modu...
متن کاملFuture trends in aberration-corrected electron microscopy.
The attainable specimen resolution is determined by the instrumental resolution limit d(i) and by radiation damage. Solid objects such as metals are primarily damaged by atom displacement resulting from knock-on collisions of the incident electrons with the atomic nuclei. The instrumental resolution improves appreciably by means of aberration correction. To achieve atomic resolution at voltages...
متن کاملAn in situ nanoindentation specimen holder for a high voltage transmission electron microscope.
We describe in detail, the design, construction, and testing of a specimen holder that allows for the nanoindentation of surfaces while viewing in cross-section in a high voltage transmission electron microscope (TEM). This nanoindentation specimen holder, having three-axis position control of a diamond indenter in combination with micromachined specimens, allows for the first time the dynamic ...
متن کاملInvestigation of Electron Beam Induced Mass Loss of Embedding Media in the Low Voltage STEM
The STEM (scanning transmission electron microscope) is useful device combining features of scanning and transmission electron microscopes. The sample in form of ultrathin section is scanned by the electron probe and the transmitted electrons are detected. Except the dedicated STEMs [1] this mode can exist as options in both TEM and SEM [2]. The STEM based on the SEM equipped by a transmission ...
متن کاملDevelopment of an environmental high-voltage electron microscope for reaction science.
Environmental transmission electron microscopy and ultra-high resolution electron microscopic observation using aberration correctors have recently emerged as topics of great interest. The former method is an extension of the so-called in situ electron microscopy that has been performed since the 1970s. Current research in this area has been focusing on dynamic observation with atomic resolutio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultramicroscopy
دوره 145 شماره
صفحات -
تاریخ انتشار 2014