Divertor Configuration and Heat Load Studies for the Aries-cs Fusion Power Plant
نویسندگان
چکیده
The critical issue of divertor configuration for heat and particle flux control in a conceptual ARIES compact stellarator (CS) reactor is addressed. The goal is to determine a divertor location and geometry with a peak heat load of not more than 10 MW/m2 for a CS equilibrium based on the configuration to be used in the NCSX experiment, optimized for high beta (6.4%) and designed for low alpha-particle power loss fraction ( 5%). The surface heat flux on the target has three components: thermal particles, lost energetic alphas, and radiation from the core and the scrape-off layer. The first two components are dominant and their magnitudes can be comparable. To maintain a tritium-breeding ratio of 1.1, the total target area should not exceed 15% of the boundary plasma surface area. The divertor concept consists of two pairs of target plates per field period, one pair each at the top and bottom of the plasma. The heat flux profile is assessed by assuming that the parallel transport can be represented by field line mapping and that cross-field transport can be modeled with a prescribed field line diffusion scheme. In this manner, the poloidal and toroidal extents of the plates and their shape and distance to the plasma are designed to intercept all the heat flux and to minimize the peak thermal heat load. An approximate scheme, based on particle drift orbits in the core and field line tracing in the edge, is derived to estimate the alpha-particle heat load distribution over the plates and the first wall. The best plate configuration to date yields total peak heat loads (thermal alpha) ranging from 5 to 18 MW/m2. Further optimization of the target plates is required to reach the design goal, which will be addressed in a future study.
منابع مشابه
Configuration Design and Maintenance Approach for the Aries-cs Stellarator Power Plant
The ARIES-CS compact stellarator study consists of a three-phase effort resulting in an integrated and detailed design study of a compact stellarator power plant. During the earlier phases, the engineering effort was focused on scoping studies of the power core design and maintenance schemes to help identify and understand the key advantages and issues associated with different configuration de...
متن کاملUWFDM-1331 Analysis of Radiation Streaming Through ARIES-CS He-Access Pipes using Two- and Three-Dimensional Analyses
Neutron streaming through penetrations compromises the shielding performance of fusion devices. To characterize the problem, the effects of neutron streaming through the divertor Heaccess pipe on the peaking of radiation-induced damage across the ARIES-CS power plant components were compared to the nominal values for the different components. The results show that due to streaming the damage ex...
متن کاملEngineering challenges in designing an attractive compact stellarator power plant
This paper summarizes the key engineering outcomes from the ARIES-CS study. The most promising power plant concept is escribed. The engineering design of the fusion power-core components (including the blanket and divertor) and the coil structural esign are briefly described along with a summary of the key results from the detailed neutronics, stress, thermal-hydraulic and ower cycle analyses p...
متن کاملSafety Assessment of the Aries Compact Stellarator Design
ARIES-CS is a 1000 MW(electric) compact stellarator conceptual fusion power plant design. This power plant design contains many innovative features to improve the physics, engineering, and safety performance of the stellarator concept. ARIES-CS utilizes a dualcooled lead lithium blanket that employs low-activation ferritic steel as a structural material, with the first wall cooled by helium and...
متن کاملDesign Optimization of High-performance Helium-cooled Divertor Plate Concept
A helium-cooled plate-type divertor design concept has being proposed within the framework of the ARIES power plant study. W tiles are used as sacrificial armor, W-alloy as main structural material and advanced ODS (oxide dispersion-strengthened) steel as the coolant manifold. An impinging jet cooling scheme is employed to enhance the heat transfer characteristics of the concept in the high hea...
متن کامل