Voltage linearity of scale factor and wave shape parameters of UHV impulse voltage dividers

نویسنده

  • Y LI
چکیده

Determining the voltage linearity of a large impulse voltage divider used in the testing of ultra-high-voltage (UHV) equipment is a challenging task. This leads to the question of whether the uncertainty requirements, specified in the present edition of IEC60060 [1, 2], can be met in the UHV range. This paper presents the results of voltage divider linearity tests at voltages up to 2400 kV. Measurements of the voltage linearity of the divider scale factor (or peak voltage), as well as the voltage linearity of the time parameters, are presented. Methods for calculating the linearity values and their interpretation are discussed. It is concluded that achieving voltage linearity of less than 3% for scale factor and voltage linearity of less than 5% for time parameters may be difficult for dividers used for testing in the UHV range. Other voltage linearity methods should be studied in order to appropriately specify measurement uncertainties for impulse testing in the UHV range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterisation at Low Voltage of Two Reference Lightning Impulse Dividers

An effort is pursued by several European National Measurement Institutes to lower the uncertainties in calibration of UHV measuring systems for lighting impulse. To this end, several reference dividers are investigated as regards their accuracy both for amplitude and for time parameters. At SP RISE Research Institutes of Sweden, a 500 kV resistive reference divider has been in use since 2000. A...

متن کامل

Influence of Coaxial Cable on Response of High- Voltage Resistive Dividers

An effort is pursued by several European National Measurement Institutes to lower the uncertainties in calibration of UHV measuring systems for lightning impulse. To this end, several reference dividers are investigated as regards their accuracy both for amplitude and for time parameters. During these investigations a deterioration of step response was identified when longer coaxial cables were...

متن کامل

Influence of the Parameters of Disk Winding on the Impulse Voltage Distribution in Power Transformers

Overvoltage distribution along the transformer winding must be uniform to certify the safety of the operation of the power transformer. Influence of the parameters variation on the impulse voltage distribution (IVD) in disk winding transformer is going to be analyzed which hasn’t been analyzed on this type of winding in the previous papers. In this research, a transformer with disk winding and ...

متن کامل

The Voltage and Time Parameter Measurement Uncertainties of a Large Damped Capacitor Divider due to its Non-ideal Step Response

Limited frequency response of impulse voltage dividers contributes to the measurement errors of the peak voltage and time parameters. This paper investigates the convolution method for the determination of the errors of lightning impulse parameters due to non-ideal step responses. The step response of a damped capacitor divider with a voltage rating of 2.2 MV was measured and analytical lightni...

متن کامل

Comparative High Voltage Impulse Measurement

A facility has been developed for the determination of the ratio of pulse high voltage dividers over the range from 10 kV to 300 kV using comparative techniques with Kerr electro-optic voltage measurement systems and reference resistive voltage dividers. Pulse voltage ratios of test dividers can be determined with relative expanded uncertainties of 0.4 % (coverage factor k = 2 and thus a two st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011