In situ measurement of absorption in high-power interferometers by using beam diameter measurements.
نویسندگان
چکیده
We present a simple technique to make in situ measurements of the absorption in the optics of high-power laser interferometers. The measurement is particularly useful to those commissioning large-scale high power optical systems.
منابع مشابه
اندازهگیری ضریب شکست غیر خطی در شیشههای آلاییده به بلورهای نیمرسانا
There are several techniques in use for non-linear refractive index measurement, namely, interferometric techniques, in which conventional inter-ferometers are used, degenerate for wave mixing (DFWM), and z-scan, Each of these techniques suffers from some shortcmings. For example conventional interferometers like Fabry-Perot and Twyman-Green need high quality optical components, unwanted refl...
متن کاملThe Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible
Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...
متن کاملDirect measurement of absorption-induced wavefront distortion in high optical power systems.
Wavefront distortion due to absorption in the substrates and coatings of mirrors in advanced gravitational wave interferometers has the potential to compromise the operation and sensitivity of these interferometers [Opt. Lett.29, 2635-2637 (2004)]. We report the first direct spatially-resolved measurement, to our knowledge, of such wavefront distortion in a high optical power cavity. The measur...
متن کاملEffect of Material and Wall Thickness Buildup Caps on the Head ScatterFactor Measurements in Irregular Fields Shielded by Cerrobend
Introduction: The head scatter factor (Sc) is important to measurements radiation beam and beam modeling of treatment planning systems used for advanced radiation therapy techniques. This study aimed to investigate the design of a mini-phantom to measurement variations in collimator Sc in the presence of shielding blocks for shaping the beam using different field sizes. <str...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 31 4 شماره
صفحات -
تاریخ انتشار 2006