An advanced slit-image camera.

نویسنده

  • N Brown
چکیده

Precision slit-image photographs of the anterior segment of the eye are capable of giving information about the dimensions and densities (light-scattering properties) of the refractive structures of the eye, which is not obtainable by direct inspection, and of providing a record of progress. Slit-image pictures were first used for this purpose by Goldmann (I940). For a slit-image photograph to be suitable for measurement it should be in perfectly sharp focus in all parts, the slit beam should cut exactly the same section of the eye on each occasion, and this section should be as nearly as possible along the optic axis of the eye. Valid comparisons can then be made between the same eye on different occasions and between different eyes. For density measurements a standard density reference needs to be incorporated in each slit-image picture (Fig. i).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

متن کامل

Panoramic Mosaics of Slit Images with Depth

In this paper, we present a new image based rendering technology called panoramic mosaics of slit images with depth. By limit camera motion only in a horizontal plane, a slit image with united depth value is used as the element of rendering. Compared with panorama, this method can support the movement of virtual camera. Multiple panoramic mosaics of slit images with depth can be joined up to pr...

متن کامل

A Range Finder by Using a Rotary Cubic Mirror

The slit light scanning method is a conventional method of range finder. But according to this method, it is impossible to measure the three dimensional shape when the object is too large, because camera is fixed against the observation field. In this paper, we propose a new active range finder with a rotary cubic mirror to solve these problems. In this sensing system, slit light and view of ca...

متن کامل

Geometry of Two-Slit Camera

We analyze the geometry of the two-slit camera and come to two conclusions. First, we show that the definition given by et al. [9] makes sense only if the two slits are not intersecting. Secondly, we prove that the complete image from a two-slit camera cannot be obtained as an intersection of the rays of the two-slit camera with a plane in space. Motivated by the quest for a unified representat...

متن کامل

Mosaicking and enhancement of slit lamp biomicroscopic fundus images.

AIMS To process video slit lamp biomicroscopic fundus image sequences in order to generate wide field, high quality fundus image montages which might be suitable for photodocumentation. METHODS Slit lamp biomicroscopic fundus examination was performed on human volunteers with a contact or non-contact lens. A stock, charge coupled device camera permitted image capture and storage of the image ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 56 8  شماره 

صفحات  -

تاریخ انتشار 1972