Intradialytic glucose infusion increases polysulphone membrane permeability and post-dilutional haemodiafiltration performances.

نویسندگان

  • F Vaussenat
  • B Canaud
  • J Y Bosc
  • M Leblanc
  • H Leray-Moragues
  • L J Garred
چکیده

INTRODUCTION During real-time monitoring of the ultrafiltration coefficient (Kuf) in haemodiafiltration (HDF), it was noticed that the ultrafiltration performance of polysulphone membrane dialysers increased when hypertonic glucose (D50%) was administered through the venous blood return. METHODS This observation was explored in six non-diabetic chronic dialysis patients during 48 HDF sessions using 1.8 m(2) polysulphone membrane dialysers. In all six patients, 24 sessions were performed with glucose supplementation (as a continuous D50% (500 g/l) infusion at 40 ml/h) and 24 sessions without supplementation. RESULTS Glucose supplementation led to a marked increase in Kuf from 22.8+/-2.2 (without D50%, n=24) to 32. 1+/-3.9 ml/h/mmHg (with D50%, n=24) (P<0.0001). An increase in percentage reduction ratios for urea and creatinine were also consistently observed during the sessions with glucose administration (from respective mean values of 75+/-5 and 68+/-4% to 79+/-4 and 74+/-10%). Mean double-pool Kt/V, calculated from serum urea concentrations, rose from 1.65+/-0.24 (n=24) to 1.86+/-0.24 (n=24) (P<0.005). Similar results were observed in a subgroup of 18 HDF sessions (nine with glucose and nine without) monitored with an on-line urea sensor of spent dialysate. No detrimental effects were induced at any time. CONCLUSIONS We conclude that intravenous glucose administration during high-flux HDF using polysulphone membranes increases significantly both ultrafiltration capacity and dialysis dose delivery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tailoring high-cut-off membranes and feasible application in sepsis-associated acute renal failure: in vitro studies.

BACKGROUND As removal of pro-inflammatory cytokines is limited in conventional diffusive or convective extracorporeal therapies, we studied in two polysulphone membranes with an industrial albumin sieving coefficient of 0.05 (Type A) and 0.13 (Type B) cytokine (IL-6, IL-8, IL-1beta, IL-1ra, TNF-alpha) and plasma protein (albumin, cystatin C, total proteins) permeability profiles. Based on the c...

متن کامل

Acute effect of haemodialysis on arterial stiffness: membrane bioincompatibility?

BACKGROUND Repetitive endothelial damage from dialysis membrane incompatibility is a probable cause of accelerated atherosclerosis in haemodialysis patients. Consequently pulse wave velocity (PWV), a measure of arterial stiffness, was utilized as a surrogate marker of vascular dysfunction during dialysis with two commonly used synthetic dialysers. METHODS PWV was monitored before, during and ...

متن کامل

Intradialytic administration of daptomycin in end stage renal disease patients on hemodialysis.

BACKGROUND AND OBJECTIVES Infusion of intravenous antibiotics after hemodialysis (HD) may delay initiation of treatment for the next HD shift. Intradialytic administration of drugs such as vancomycin during the final hour of HD obviates these delays. Daptomycin has potent activity against Gram-positive bacteria, but the manufacturer recommends that the dose be infused after HD ends. This study ...

متن کامل

Nano composite PEBAX®/PEG membranes: Effect of MWNT filler on CO2/CH4 separation

The performances of two-phase polymer-liquid PEBAX®/polyethylene glycol (PEG) and three-phase polymer-liquid-solid PEBAX®/PEG/MWNT thin film composite membranes for CO2 and CH4 permeation were studied. The effect of temperature and MWNT/PEBAX® ratio on single gas (CO2 and CH4) permeability was investigated. The permeat...

متن کامل

Nano composite PEBAX®/PEG membranes: Effect of MWNT filler on CO2/CH4 separation

The performances of two-phase polymer-liquid PEBAX®/polyethylene glycol (PEG) and three-phase polymer-liquid-solid PEBAX®/PEG/MWNT thin film composite membranes for CO2 and CH4 permeation were studied. The effect of temperature and MWNT/PEBAX® ratio on single gas (CO2 and CH4) permeability was investigated. The permeat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2000