Prostate Intrafraction Motion Assessed by Simultaneous Kv

نویسندگان

  • JUSTUS D. ADAMSON
  • Qiuwen Wu
  • Jay Burmeister
چکیده

PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KV FLUOROSCOPY AT MV DELIVERY by JUSTUS D. ADAMSON August 2009 Co-Advisor: Dr. Qiuwen Wu Co-Advisor: Dr. Jay Burmeister Major: Medical Physics Degree: Doctor of Philosophy Purpose: To investigate the use of a gantry mounted kV imager for prostate intrafraction motion measurement during simultaneous dose delivery. Materials & Methods: We developed an algorithm to register fluoroscopy images with reference images of implanted fiducials derived from daily CBCT. We investigated the relationship between imaging dose and 2D registration accuracy for fiducial localization with and without the presence of MV contamination. Prostate motion during radiotherapy was simulated using existing cine-MRI measurements, and was used to evaluate various techniques to estimate a 3D prostate trajectory from 2D localizations. Motion was measured for each fraction of 22 patients receiving hypofractionated IMRT, and was used to: (1) investigate the ability of preand post-treatment CBCT to predict intrafraction motion, (2) describe motion characteristics and their dosimetric effects, (3) evaluate adaptive strategies for intrafraction motion management after online correction for interfraction motion. Results: With fractional imaging dose being 2mGy (~10% of a CBCT acquisition), fiducials were localized at each beam with error <1mm for 95% of registrations. Images acquired during MV dose delivery require increased mAs to obtain equal accuracy, with mAs/registration increasing roughly linearly with field size and dose rate. 3D error was <1.5mm for 95% of localizations when the 3D trajectory was assumed to be the shortest path satisfying all 2D localizations. Rectal filling status from volumetric imaging was a significant predictor of prostate intrafraction motion, and probability of motion increased with treatment duration. After online correction of interfraction motion, the overall probability of a 3mm and 5mm prostate displacement during treatment delivery was 30% and 10%, but ranged from 1%-94% and 0%-59% for individual patients. With 3mm margins, reduction in CTV D99 was ≤5% for ~95% of patients (21/22), but was 15.3% for the one exception and was apparent after 5 fractions. Adaptive strategies including prediction and correction of patient specific systematic error and patient specific geometric margin calculation are feasible. Conclusions: Prostate intrafraction motion evaluation using kV fluoroscopy during dose delivery can be performed accurately with low dose, and is useful for adaptive management of intrafraction motion after online correction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.

PURPOSE The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. METHODS AND MATERIALS In this prospecti...

متن کامل

Real‐time intrafraction prostate motion during linac based stereotactic radiotherapy with rectal displacement

BACKGROUND Kilovoltage Intrafraction Monitoring (KIM) is a method which determines the three-dimensional position of the prostate from two-dimensional kilovoltage (kV) projections taken during linac based radiotherapy treatment with real-time feedback. Rectal displacement devices (RDDs) allow for improved rectal dosimetry during prostate cancer treatment. This study used KIM to perform a prelim...

متن کامل

Prostate stereotactic body radiotherapy with simultaneous integrated boost: which is the best planning method?

BACKGROUND The delivery of a simultaneous integrated boost to the intra-prostatic tumour nodule may improve local control. The ability to deliver such treatments with hypofractionated SBRT was attempted using RapidArc (Varian Medical systems, Palo Alto, CA) and Multiplan (Accuray inc, Sunnyvale, CA). MATERIALS AND METHODS 15 patients with dominant prostate nodules had RapidArc and Multiplan p...

متن کامل

First demonstration of combined kV/MV image-guided real-time dynamic multileaf-collimator target tracking.

PURPOSE For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. METHODS AND MATERIALS The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millenniu...

متن کامل

Intrafraction motion of the prostate during an IMRT session: a fiducial-based 3D measurement with Cone-beam CT

BACKGROUND Image-guidance systems allow accurate interfractional repositioning of IMRT treatments, however, these may require up to 15 minutes. Therefore intrafraction motion might have an impact on treatment precision. 3D geometric data regarding intrafraction prostate motion are rare; we therefore assessed its magnitude with pre- and post-treatment fiducial-based imaging with cone-beam-CT (CB...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009