Reliability of sentinel lymph node mapping with biopsy for head and neck cutaneous melanoma.
نویسندگان
چکیده
OBJECTIVES To determine (1) the reliability of sentinel lymph node mapping with biopsy (SLNB) in head and neck cutaneous melanoma to accurately stage nodal basins and (2) the safety of SLNB in both the neck and parotid regions. DESIGN Retrospective cohort study with a median follow-up of 25 months. All patients had a minimum follow-up of 1 year. SETTING Academic medical center. PATIENTS Eighty evaluable patients diagnosed as having head and neck cutaneous melanoma and staged using SLNB. INTERVENTIONS Sentinel lymph nodes were identified using preoperative lymphoscintigraphy and a combination of intraoperative gamma probe and isosulfan blue dye. Patients with a SLN positive for melanoma underwent therapeutic lymphadenectomy followed by an evaluation for adjuvant therapies. Patients with a negative SLNB result were followed up clinically. MAIN OUTCOME MEASURES Percentage of positive SLNs, regional recurrence in the setting of a negative SLNB result (false-negative rate), and procedure complications. RESULTS The mean Breslow depth was 2.35 mm. A SLN was identified in 77 (96.3%) of cases, with an average of 2.18 nodes per patient. Of the sentinel nodes identified, 74% were from the neck region. The remaining 26% were from the parotid basin. No facial nerve complications occurred. Of the patients, 14 (18%) were SLN positive for metastatic melanoma. The regional failure rate in the setting of a negative SLNB result was 4.5%. CONCLUSIONS Sentinel lymph node mapping with biopsy is a reliable technique to diagnose regional spread from head and neck cutaneous melanoma. This procedure can be performed in both neck and parotid nodal basins with safety and accuracy similar to non-head and neck sites.
منابع مشابه
Sentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid
Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...
متن کاملMapping of specific sentinel node locations for skin cancer of the head.
In current dermatological practice lymphatic mapping and sentinel lymph node biopsy (SLNB) are frequently used in patients with cutaneous cancers, like malignant melanoma, squamous cell carcinoma and Merkel cell carcinoma. However, those tumors are often located on the head and neck, regions with notoriously variable lymphatic drainage patterns. Consequently, the incidence of successful SLNB in...
متن کاملRecurrence of cutaneous melanoma of the head and neck after negative sentinel lymph node biopsy.
BACKGROUND Sentinel lymph node biopsy remains controversial for cutaneous melanoma of the head and neck (CMHN). Incidence and factors associated with recurrence after negative sentinel lymph node biopsy have not been well delineated. METHODS Characteristics of 204 patients with head and neck melanoma who had a negative sentinel lymph node biopsy were studied. Main outcomes were overall surviv...
متن کاملSentinel lymph node biopsy correctly predicts regional lymph node recurrence in trunk malignant melanoma with multiple drainage basins
We report a young male with an initial excisional biopsy report of melanoma of the lower back, referred to our hospital for complete excision and sentinel lymph node (SLN) biopsy. Four peritumoral intradermal Tc-99m phytate injection was performed and SLNs were detected in both axillary and right inguinal regions. On the biopsy only the right axillary SLN was metastatic leading to right axilla...
متن کاملAbstract 49. ICG Fluorescence with Lymphoscintigraphy for Sentinel Node Biopsy in Head and Neck Cutaneous Melanoma: A Reproducible, Reliable Means to Improve False Negative Rates
PURPOSE: Head and neck melanoma is associated with a high false negative sentinel lymph node biopsy (SLNB) rate. Our group previously demonstrated the combination of radiotracer and ICG SPY Elite navigation system was feasible and more sensitive compared to standard vital dye and radioactive tracer for SLNB. The goal of this report was to analyze our experiences utilizing ICG fluorescence with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of otolaryngology--head & neck surgery
دوره 129 1 شماره
صفحات -
تاریخ انتشار 2003