Security and cost comparison of INR self-testing and conventional hospital INR testing in patients with mechanical heart valve replacement

نویسندگان

  • Qiu-lin Chen
  • Li Dong
  • Yi-jun Dong
  • Shu-lin Zhao
  • Bo Fu
  • Yu-qing Wang
  • Hong Jiang
چکیده

BACKGROUND International normalized ratio (INR) self-testing can improve the management of anticoagulation therapy with warfarin for the patients following mechanical heart valve replacement. Several reviews and studies have demonstrated self-management as an option to improve patient's outcome considerably after mechanical heart valve replacement. We sought to analyze the security, economy and discuss the prospect of self-testing of anticoagulation therapy in patients following mechanical heart valve replacement in China, and evaluate the accuracy and stability of CoaguChek XS portable INR-testing device. METHODS This was a prospective self-controlled clinical study conducted with 526 patients receiving oral warfarin anticoagulation therapy after mechanical heart valve replacement in the period of Mar.1, 2012 - Nov.1, 2012 in Cardiovascular Surgery Department of West China Hospital of Sichuan University. The same patient performed INR testing with CoaguChek XS portable coagulometer (group1) and central lab (group 2) in parallel. The follow-up time was 6 months. Meanwhile, a questionnaire was handed out to survey the expenses required for the re-examination visits to the hospital, time, and anticoagulation complications. RESULTS No severe anticoagulation complications occurred in all the patients. No significant difference of the INR results were observed between group 1 and group 2, they showed significant relevance, r = 0.953(p < 0.05). Compared with the conventional method of INR testing in hospital, the portable coagulometer is convenient, quick and less traumatic. Self-testing of anticoagulation therapy reduced the cost and the time required for re-examination. CONCLUSIONS Results of CoaguChek XS monitor are precise and have a good consistency and stability as compared with traditional laboratory testing. For the patients receiving anticoagulation therapy after mechanical heart valve replacement, the self-testing of anticoagulation therapy with portable coagulometer is a safe choice, and it has a promising future application in China.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INR self-management permits lower anticoagulation levels after mechanical heart valve replacement.

BACKGROUND The Early Self Controlled Anticoagulation Trial (ESCAT I) showed that anticoagulation self-management after mechanical heart valve replacement decreased complication rates by maintaining INR levels closer to the target range than International Normalized Ratio (INR) home doctor management. The therapeutic range for the INR in that study was between 2.5 and 4.5 for all positions of pr...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Telemedicine-guided, very low-dose international normalized ratio self-control in patients with mechanical heart valve implants.

AIM To study in patients performing international normalized ratio (INR) self-control the efficacy and safety of an INR target range of 1.6-2.1 for aortic valve replacement (AVR) and 2.0-2.5 for mitral valve replacement (MVR) or double valve replacement (DVR). METHODS AND RESULTS In total, 1304 patients undergoing AVR, 189 undergoing MVR and 78 undergoing DVR were randomly assigned to low-dos...

متن کامل

Comparison of Group and Individual Training on the Patients’ Compliance and Incidence of Warfarin Side Effects after Cardiac Valve Replacement

Introduction: Oral anticoagulant therapies are intended for prevention of thrombotic adverse effects and to maintain the level of drug without bleeding. The probability of risk highly depends on the patient compliance after discharge from hospital. This study was designed to compare the effect of group and individual education on patients’ compliance and incidence of adverse effects of warfarin...

متن کامل

Comparison between Prothrombin Complex Concentrate (PCC) and Fresh Frozen Plasma (FFP) for the Urgent Reversal of Warfarin in Patients with Mechanical Heart Valves in a Tertiary Care Cardiac Center

Fresh frozen plasma (FFP) and prothrombin complex concentrate (PCC) reverse oral anticoagulants such as Warfarin. We compared the standard dosage FFP and PCC in terms of efficacy and safety for patients with mechanical heart valves undergoing interventional procedures while receiving Warfarin. Fifty patients were randomized (25 for each group) with mechanical heart valves [international normali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015