Stroke volume variation and pleth variability index to predict fluid responsiveness during resection of primary retroperitoneal tumors in Hans Chinese.

نویسندگان

  • Q Fu
  • W D Mi
  • H Zhang
چکیده

Respiration variation in arterial pulse pressure (ΔPP) and pulse oximetry plethysmographic waveform amplitude (ΔPOP) are accurate predictors of fluid responsiveness in mechanically ventilated patients. We hypothesized that stroke volume variation (SVV) and pleth variability index (PVI) can predict fluid responsiveness in mechanically ventilated patients during major surgical procedures in Hans Chinese. This prospective study consisted of fifty-five Hans Chinese patients undergoing resection of primary retroperitoneal tumors (PRPT). During the surgical procedures, hemodynamic data [central venous pressure (CVP), cardiac index (CI), stroke volume index (SVI), SVV, and PVI] were recorded before and after volume expansion (VE) (8 ml•kg-1 of 6% hydroxyethyl starch 130/0.4). Fluid responsiveness was defined as an increase in SVI ≥ 10% after VE. Four patients were excluded from analysis for arrhythmia or obvious hemorrhage during VE. Baseline SVV correlated well with baseline PVI and the changes in SVV was correlated with the changes in PVI (p < 0.01) after VE. There were significant increases of CI, SVI and decreases of SVV, PVI in responder (Rs) after VE. ROC results showed that the areas for SVV, PVI were significantly higher than the areas for CI, MAP, CVP, PI (p < 0.05). The best threshold values to predict fluid responsiveness were more than 12.5% for SVV and more than 13.5% for PVI in the real surgical setting. The baseline value of SVV, and PVI correlated significantly with volume-induced changes in SVI (p < 0.01). Both SVV and PVI could be used to predict intraoperative fluid responsiveness during resection of PRPT in Hans Chinese.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pleth Variability Index predicts fluid responsiveness in critically ill patients

OBJECTIVE To investigate whether the pleth variability index, a noninvasive and continuous tool, can predict fluid responsiveness in mechanically ventilated patients with circulatory insufficiency. DESIGN Prospective study. SETTING Surgical intensive care unit of a university hospital. PATIENTS Forty mechanically ventilated patients with circulatory insufficiency in whom volume expansion ...

متن کامل

Non-invasive prediction of fluid responsiveness in infants using pleth variability index.

This prospective study assessed whether respiratory variations in velocity time integral, peak blood flow velocity and non-invasive pleth variability index are useful measurements in infants undergoing congenital heart surgery and determined threshold values that may help guide fluid administration. In 27 infants receiving mechanical ventilation, of mean (SD) weight 10.4 (6.3) kg, 13 increased ...

متن کامل

Accuracy of the pleth variability index to predict fluid responsiveness depends on the perfusion index.

BACKGROUND Respiratory variations in plethysmographic waveform amplitudes derived from pulse oximetry are believed to predict fluid responsiveness. The non-invasive pleth variability index (PVI) is a variable based on the calculation of changes in the perfusion index (PI). The aim of the following study was to examine whether the predictive power of PVI depends on different values of PI. METH...

متن کامل

Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery.

BACKGROUND AND OBJECTIVE Accurate assessment of a patient's volume status is an important goal for an anaesthetist. However, most variables assessing fluid responsiveness are either invasive or technically challenging. This study was designed to compare the accuracy of arterial pressure-based stroke volume variation (SVV) and variations in the pulse oximeter plethysmographic waveform amplitude ...

متن کامل

Changes in pleth variability index and detection of hypotension during spinal anaesthesia for caesarean section.

Background: Hypotension occurs commonly during caesarean section under spinal anaesthesia. As the onset may be rapid, it may fail to be detected by non-invasive blood pressure (BP) measurement in a timely fashion. Pulse oximeters can continuously and non-invasively measure tissue perfusion (perfusion index (PI)) and its variation with the respiratory cycle (pleth variability index (PVI)). As wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bioscience trends

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2012