Bipolar Pulsed Reset for AC Coupled Charge-Sensitive Preamplifiers

نویسندگان

  • D. A. Landis
  • N. M. Madden
  • F. S. Goulding
  • Earnest Orlando
چکیده

A new type of charge restoration is described for use particularly in germanium gamma-ray spectrometers for accelerator and space physics applications. A bipolar pulsed reset technique is appIied to these applications for the first time. This technique overcomes the problems introduced by the need to AC couple detectors and the fact that very large energy depositions occur due to charged particles present in substantial fluxes, particularly in space. The circuit is described and experimental results are presented and discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse-height loss in the signal readout circuit of compound semiconductor detectors

Compound semiconductor detectors such as CdTe, CdZnTe, HgI2 and TlBr are known to exhibit large variations in their charge collection times. This paper considers the effect of such variations on the measurement of induced charge pulses by using resistive feedback charge-sensitive preamplifiers. It is shown that, due to the finite decaytime constant of the preamplifiers, the capacitive decay dur...

متن کامل

Pulsed bipolar CMOS imager

This paper will describe an active pixel CMOS-compatible imager aimed at high resolution still cameras. We will discuss pixel operation, column sense circuits, serial output, and show results from existing imagers. In this abstract, we show results from a prototype 640x480 imager with 5.9x5.9 μm2 pixels built in 0.8 μm double-poly CMOS with one additional base implant. Active Capacitor-coupled ...

متن کامل

Electronic noise in charge sensitive preamplifiers for X-ray spectroscopy and the benefits of a SiC input JFET

A comprehensive summary and analysis of the electronic noise affecting the resolution of X-ray, γ-ray and particle counting spectroscopic systems which employ semiconductor detectors and charge sensitive preamplifiers is presented. The noise arising from the input transistor of the preamplifier and its contribution to the total noise is examined. A model for computing the noise arising from the...

متن کامل

Low-Intensity Electron Beam Monitoring and Beam Applications at OPU Linac

Low intensity beams are generated with a 18 MeV Sband electron linear accelerator at Osaka Prefecture University. The minimum charge of electrons in a pulsed beam is about several aC. Study has been made to establish the methods for measuring the intensity and the spatial profile of the beam at electron charges of a beam in aC to pC regions. In pC region a beam monitor using a charge-sensitive ...

متن کامل

A High Resolution CMOS Imager with Active Pixel using Capacitively Coupled Bipolar Operation

The active pixel sensor technology promises high performance than conventional CCD imagers. This paper reports a new high resolution CMOS imager with one transistor active pixel sensing based on capacitorcoupled bipolar action. The base capacitor is pulsed negatively for image integration and positively for image sensing. The pixel size is 5.9um x 5.9um (on 0.8um design rule). The prototype ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008