Comparison of valve resistance with effective orifice area regarding flow dependence.
نویسندگان
چکیده
Aortic valve resistance has been proposed to represent the severity of aortic stenosis because some studies observed that it was less affected by change in flow than the valve-effective orifice area, but this issue remains controversial. The objective of this study was to systematically analyze the theoretical and practical determinants of these parameters in relation to changes in flow. Valve area and resistance in different valves were studied in vitro in a pulse duplicator system at different flow rates and in vivo in 90 subjects referred to either exercise or dobutamine infusion. Theoretical analysis and experimental results both demonstrated a unique relation between resistance (RES), valve-effective orifice area (EOA), and flow rate (Q): RES = K x (Q/EOA(2)). Accordingly, in fixed stenoses or in mechanical valves, resistance increased markedly with flow rate both in vitro (+0.88 +/- 0.26%/% of flow increase) and in vivo (mechanical valves: +2.09 +/- 4.61, fixed stenotic valves: +0.59 +/- 0.32%/%), whereas valve area did not change significantly (<0.2%/%). In contrast, in valves with a flexible orifice (bioprostheses and some patients with aortic stenosis), resistance was less increased due to the increase in valve area. Thus, both from a theoretical and a practical standpoint, valve resistance is much more flow dependent than valve area, particularly in fixed stenoses. Situations in which resistance does not increase with flow rate are unpredictable and are found in flexible valves when there is a concomitant increase in valve area.
منابع مشابه
Doppler Assessment of Prosthetic Valve Orifice Area
Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...
متن کاملDoppler assessment of prosthetic valve orifice area. An in vitro study.
BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...
متن کاملA new approach for the evaluation of the severity of coarctation of the aorta using Doppler velocity index and effective orifice area: in vitro validation and clinical implications.
Early detection and accurate estimation of COA severity are the most important predictors of successful long-term outcome. However, current clinical parameters used for the evaluation of the severity of COA have several limitations and are flow dependent. The objectives of this study are to evaluate the limitations of current existing parameters for the evaluation of the severity of coarctation...
متن کاملEstimation of aortic valve effective orifice area by Doppler echocardiography: effects of valve inflow shape and flow rate.
BACKGROUND The effective orifice area (EOA) is the standard parameter for the clinical assessment of aortic stenosis severity. It has been reported that EOA measured by Doppler echocardiography does not necessarily provide an accurate estimate of the cross-sectional area of the flow jet at the vena contracta, especially at low flow rates. The objective of this study was to test the validity of ...
متن کاملMitral Ball-Valve Prosthesis
REPLACEMENT of nonfunctioning valves is a significant recent advancement in the correction of cardiac valvular disease. The most widely used artificial device replacing the mitral valve is the Starr-Edwards ballvalve prosthesis.' Its effectiveness was shown in recent reports by the marked clinical improvement in properly selected patients.2 However, cardiologists and cardiac surgeons are faced ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of cardiology
دوره 88 1 شماره
صفحات -
تاریخ انتشار 2001